background image

INSTALLATION GUIDE

7

6

INSTALLATION GUIDE

Remove all packaging materials from the box and ensure all components and parts

are complete.

FAN ASSEMBLY

1.   Assemble the pulley, bolt and pipe together as shown:

            Cotter pin must be fixed into the bolt and bent.

   Warning: May cause injuries if ceiling fan drops

WARNING

   Do not use a modified pipe. Ensure the bolt is 

   attached securely to the pipe to prevent the ceiling fan from falling and causing 

   injuries.

4.Place the cap on to the motor shaft. Proceed to assemble 

   the pipe with the motor shaft and secure them in place 

   using the bolt, plain washer, spring washer, nut and cotter 

   pin. Complete the assembly by bending the cotter pin.

            Cotter pin must be fixed into the bolt and bent.

   Warning: May cause injuries if ceiling fan drops

            Firmly tighten the bolt and nut using two 

            wrenches as shown.

   Ensure the pipe has been fully tightened to the motor shaft.

   Bolt tightening torque is 800 – 1200 Necm 

   (181.7 – 122. 4 Kgfecm).
   Insufficient tightening may result in abnormal noise, 

   vibration or short appliance life.

   Warning: May cause injuries if fan drops.

3.Pass the cord and safety wire through the pipe and insert

   the cord spring. Remove the safety wire screw from the 

   motor shaft.

2.Slip the upper and lower canopies to the pipe.

            Do not tighten the screws

Bolt

Pipe

B

 

 

 

 

 

 

 

   

 

 

 

 

Pulley

{

5.Connect the pipe cords to the motor terminal.

   – First, connect EARTH wire {Green) to terminal "3"
   – Second, connect NEUTRAL wire (Blue) to terminal "2"
   – Lastly, connect LIVE wire (Brown) to terminal "1"

           Ensure all terminals are connected correctly by 

           suitably qualified persons to avoid the risk of 

           electric shocks and other hazards.

6. Secure the cord as shown in the illustration using the insulock tie.

           Do not secure the safety wire with the insulock tie.

           Loose insulock tie and cords touching the motor are 

           unsafe. This will result in abnormal noise and may 

           cause ceiling fan to fall.

7.Assemble the fan blades onto the motor and secure it firmly in

   place with the two (2) blade screws. Repeat until all fan blades

   are assembled correctly.

           Blades must be affixed correctly.
           Incorrect assembly may not produce desired wind 

           results. Warning: May result in injuries if blades fall.

FAN SUSPENSION

 Ceiling fan must be mounted above 2.5m from the floor 

   and at least 1m from the wall to the blade.

 Warning: Contact with blades during fan operation may 

   result in injuries.

 Ensure ceiling hook is able to support at least 20 times 

   the ceiling fan's weight.

 Warning: Improper fan assembly can cause unstable 

   air flow and cause ceiling fan to wobble.

        CAUTION

 Ensure suspension hook is installed on concrete ceiling.

 Do not install on plaster ceiling or any type of drywall ceilings.

 Do not install inside dome ceiling

 

 

 

 

 

 

 

Terminal

1
2

LIVE
NEUTRAL
EARTH

Regulator

Connect to Regulator 

“1”

”2”

”3”

3

 

{

 

 

Blade Screw

I

 

2.5M or more

B

 

 

 

 

 

 

 

 

 

 

 

 

 

Insulock Tic

Upper Canopy

 

 

 

 

Lower Canopy

 

   

 

 

 

 

 

 

 

 

 

 

Cord Spring

Cord

   

 

 

 

Safety Wire

P

 

Nut

Plain Washer

Spring Washer

Bolt

Safety Wire

Cap

Cotter Pin

 

 

   

 

 

 

 

Bolt

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INCORRECT

POSITION

Summary of Contents for MFC-Eurus 360BK

Page 1: ...ANUAL MFC Eurus 360BK MFC Eurus 360WH MFC Eurus 360BW MFC Eurus 360GR E mail electrical appliance dksh com www morgan my Market Expansion Services by www dksh com my facebook com morganappliances Ceiling Fan ...

Page 2: ... electrical shock or injury to persons or property please read and follow below instructions carefully The ceiling fan must be hooked on concrete ceiling Do not install on a plaster ceiling or any type of drywall ceilings During installation all screws must be tightened at all indicated parts Always operate the product from a power source of the same voltage frequency and rating as indicated on th...

Page 3: ...ance when relocating it The ceiling fan must be mounted above 2 5m from the floor and at least 1m from the wall to the fan blade To avoid injuries caused to users or any damage to properties please follow all the symbols with explanations written below WARNING CAUTION 1 2 3 4 5 6 9 10 11 12 15 8 7 14 13 1 Pulley 2 Bolt 3 Upper Canopy 4 Canopy Screw 5 Pipe 6 Bolt 7 Cotter Pin 8 Nut 9 Terminal 10 Lo...

Page 4: ...e Green to terminal 3 Second connect NEUTRAL wire Blue to terminal 2 Lastly connect LIVE wire Brown to terminal 1 Ensure all terminals are connected correctly by suitably qualified persons to avoid the risk of electric shocks and other hazards 6 Secure the cord as shown in the illustration using the insulock tie Do not secure the safety wire with the insulock tie Loose insulock tie and cords touch...

Page 5: ... to avoid any hazards Use only 2271EC53 RW or tube thickness of 1mm or above Please use the country s wiring regulations for other requirements such as lead wire diameter Earth Ceiling Fan Regulator Wall Switch On Off Double pole single throw switch Switch Breaker 220 240V 50Hz Power Supply N L REGULATOR INSTALLATION 1 Mount the regulator base onto the wall with screws 2 Remove the regulator cover...

Page 6: ...ations repairs electrical or mechanical adjustments Keep the fan clean regularly by wiping dirt away with a clean soft cloth mild soap and water Ensure it is dry by wiping again Do not use solvents gasoline or petrol or any abrasive cleansers to avoid damaging the exterior finishing Do not paint the fan blades If damaged order a new set of blades 3 pieces from your nearest authorized dealer or aft...