background image

6

7

INSTALLATION

NOTES FOR THE INSTALLER

INSTALLATION (VENT INSIDE)

•  Insert the inner chimney into the upper 

   chimney and pull upwards. 
   Adjust to reach 
   the height 
   required.

 

 

•  Secure the lower chimney with 2 pcs of 

   4x8mm screws.

 

 

Screw

•  An exhaust pipe is not required if there is no external exhaust outlet. See 

   similar installation method as in “Installation (Vent outside)”.

•  Charcoal filter can be used to trap odours.

•  To install the charcoal filter, the front glass 

   should be detached first. Pull the front glass 
   outwards and detached it down.

•  Insert the charcoal filter into the unit and turn it 

   clockwise.

NOTE:

•  Ensure the filter is securely locked to prevent accidents.

•  When charcoal filter attached, the suction power will be lower.

•  Every hood has two fixing screws to firmly fix the hood in its place.

CLOSE

•  Slide the chimney to adjust 

   the chimney height. When 
   the desired height is 
   achieved, secure it with 
   2 pcs of 4x8mm screws onto
   the holes as illustrated in 
   Plate I below.

Plate I

 

•  Drill 2 x 8mm holes to accommodate Plate II. 

   Secure and tighten Plate II onto the wall with 
   the 2 screws 
   provided.

•  Assemble the 

   chimney onto 
   the unit and 
   secure it with 
   2 screws.

 

Plate II

4x8mm

4x30mm

SAFETY INFORMATION

•  Power connections must be made only in accordance to the local standards and laws.

•  Ensure that the power supply complies with the setting on this appliance, otherwise, do not connect.

•  The power connection of this appliance must be earthed. If unsure, check with a qualified electrician. The

   colour codes are:

   Green & Yellow  =   EARTH

   Blue                   =   NEUTRAL

   Brown                =   LIVE

•  Ensure that the power cord is not exposed to heat sources or sharp objects.

•  LED lamp must not exceed 1.5W/7W.

TROUBLESHOOTING

PROBLEM

CAUSE

SOLUTION

No operation

No electrical supply

Ensure that power switch is turned on
Ensure power plug is connected to the power supply

Poor airflow

Aluminium grease filters are

Clean the filters and replace when dry

clogged.
Charcoal grease filters are clogged Replace charcoal filters

Motor running but no airflow

Butterfly valve jammed

Contact technician

Motor cuts after a few

High temperature safety device

The kitchen is not sufficiently ventilated

minutes

activated

The hood is installed too near the 

Ensure the hood is installed at least 65cm from the 

cooking stove

stove

Strong cooking smell

Charcoal filters are not installed

Charcoal filters must be installed in re- circulating 

mode

Oil dripping onto stove

Oil cup missing or not installed

Remove aluminium filter and replace oil cup

Aluminium grease filter saturated

Wash the aluminium grease filters

Whirring sound

Foreign object in contact with fan 

Contact technician

blade

Front

Glass