exclusion(remove), please fix the equipment in the place you want . Make sure 
the distance is under the operating range. 

Device Reset 
Press the button unlock and lock-unlock 6 times the device will send the reset 
notification to the list node in the group 1 and erases the device memory. 
Use this procedure only in the event that the network primary controller is 
missing or otherwise inoperable. 

Device Wakeup

 

Press the button unlock and lock-unlock 1 times 

Battery low warning 
When only used the 4xAAA battery that is low than 2.8V PIR will send the 
battery low warning 0xFF to the list node in the group 1.

 

According to the requirements of the national standard GB50166-92 , the 
sensor need to be tested at least once in every half a year. And it need to 
have cleaning and maintenance in every two years for the sensor which 
has been fixed.

 

The working performance for the siren is mainly influenced by the 
quality of the environment. If the siren is working under the the 
environment with dust or high wind speed , the maintenance 
period need to be shorten 

Attentions 

Disclaimer

 

If there is function or software upgrade,

 Mordomus 

won’t have any further notice . The customer can contact with us to 

consult the relevant information . Mordomus is qualified for the right 

of interpretation Interpretation. 

 

This product should be installed in the interior renovation 
completed, before installing this product should be stored in a the 
place which is dust proof, moisture pro of a mould proof.  

4

www.mordomus.com

Summary of Contents for iZSPIRF

Page 1: ...PIR sensor iZSPIRF ...

Page 2: ... illegal operation which will cause damage or property lost Maintenance Under the warranty period the unit is defected under the correct operation the manufacturer will guarantee to keep the unit in repair if consumer can provide guarantee card and purchase receipt Product Introduction This product can be included and operated in any Z Wave network with other Z Wave certified devices from other ma...

Page 3: ...llation Method Magnetron Working Voltage 4xAAA DC 5V Working Current 35mA When it is triggered Sleeping Current 20uA Working Temperature 10 50 Operating Humidity 80 Communication Technology Z Wave plus Communication Frequency 868 42 908 42 MHz Transmission Speed 9 6 40 100 kbps Transmission Distance outdoor 40M 2 www mordomus com ...

Page 4: ...button in the pir sensor when the Z Wave controller sends the instructions for exclusion Times to Press the Button unlock and lock unlock 1 time will send the NIF Remarks Please pay your attention that the detector cannot be set in the place where is over one meter distance from the controller If the controller has not yet received the signal please press the button for inclusion add exclusion rem...

Page 5: ...onal standard GB50166 92 the sensor need to be tested at least once in every half a year And it need to have cleaning and maintenance in every two years for the sensor which has been fixed The working performance for the siren is mainly influenced by the quality of the environment If the siren is working under the the environment with dust or high wind speed the maintenance period need to be short...

Page 6: ...ensor please contact us timely The battery is only a backup power use and not recommended as the main power supply The product installation shall comply with the provisions of the state standard reference GB50166 92 code for construction and acceptance of automatic fire alarm system 5 www mordomus com ...

Reviews: