Press and release the Z-Wave button quickly several times once you put the controller in 

the inclusion mode to ensure the command has gone through 

-

 

Put your controller in the EXCLUSION mode and press and release the Z-Wave button 

quickly 3 times, then try adding it to your network again 

Z-WAVE

 

EXCLUSION 

1. Bring the siren within 3 feet from your Z-Wave gateway controller
2. Put your Z-Wave controller in exclusion/unpairing mode
3. Press and release the Z-Wave button on the siren THREE TIMES quickly
4. The device should disappear from your controller's device list
Please repeat the process following all steps carefully if first attempt is unsuccessful 

FACTORY

 

RESET 

If your primary controller is missing or inoperable, you may need to reset the device to 
factory settings. To complete the process, press and hold the Z-Wave button for 10 seconds. 
NOTE: All previously recorded activity and custom settings will be erased from the siren

’s

 

memory. 

ASSOCIATION 
Once the Z-Wave siren is added to your network, you are able to trigger it with other 
components from your network, as well as control and monitor its activity from your mobile 
device, or computer. 

Depending on your Z-Wave gateway's home automation software capabilities, you may be 
able to associate your indoor siren in groups with other Z-Wave devices to schedule scenes 
and create events. Indoor siren supports Group 1 with up to five devices for lifeline 
communication (Group 2-5 is not supported). 

Please refer to your controller's user guide for advanced programming instructions as they 
are a little different for every software. 

MOUNTING 
Find the best spot for your Z-Wave indoor siren - a corner in the living room, garage ceiling, 
or anywhere else you see fit. Use the 2 screws included in the box to fix the mounting 
bracket to flat surface of your choice. 

Once the bracket is securely installed, carefully slide the siren onto the bracket and position 
it by tilting it to either side, upwards, or downwards. 

WARNING

 

-

 

This product should be installed indoors upon completion of any renovations 

-

 

Prior to installation, the device should be stored in a dry, dust- and mold-proof place 

-

 

Do not install the siren in a place with direct sun exposure, high temperature or humidity 

-

 

Keep away from chemicals, water, and dust 

-

 

Ensure the device is never close to any heat source or open flame to prevent fire 

-

 

Ensure the device is connected to an electric power source that does not exceed the 

maximum load power 

3

www.mordomus.com

Summary of Contents for iZSIRI1

Page 1: ...ices when included to a Z Wave gateway controller Z Wave Plus with improved 500 chip for faster and safer wireless communication Acts as signal repeater when powered by AC adapter Sleek design and compact size SPECIFICATIONS Model Number iZSIRI1 Z Wave Signal Frequency 908 42 MHz Volume 110dB Power DC 5V 1A and 4 AAA 1 2V batteries for back up power Range Up to 100 feet line of sight Operating Tem...

Page 2: ...r siren to your Z Wave network before mounting it Z WAVE INCLUSION 1 Bring the siren within 3 feet from your Z Wave gateway controller 2 Put your Z Wave controller in inclusion pairing mode 3 Press and release the Z Wave button on the siren THREE TIMES quickly 4 A new alarm device should appear on your controller s device list Z Wave button Q I have not been able to add the device to my network af...

Page 3: ... device or computer Depending on your Z Wave gateway s home automation software capabilities you may be able to associate your indoor siren in groups with other Z Wave devices to schedule scenes and create events Indoor siren supports Group 1 with up to five devices for lifeline communication Group 2 5 is not supported Please refer to your controller s user guide for advanced programming instructi...

Page 4: ...Y UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT STORE INDOORS WHEN NOT IN USE SUITABLE FOR DRY LOCATIONS ONLY DO NOT IMMERSE IN WATER NOT FOR USE WHERE DIRECTLY EXPOSED TO WATER This device complies with Part 15 of the FCC Rules Operation is subject to the following conditions 1 This device may not cause harmful interferenc...

Reviews: