Installation
1.
Put the in wall switch into a wall box and connect the AC power wire L,N to
iZOFC22
connector L, N.
2.
Connect the wall switch to the
iZOFC22
as Fig1 .
3.
To manually turn ON the Switch, press and release the On/Off button. The
LED will light ON for 1 second, and the load plugged into the Switch will
also turn ON.
4.
To manually turn OFF the Switch, simply press and release the On/Off
button. The LED will light ON for 1 second and the load plugged into the
Switch will turn OFF.
Symptom
Cause of Failure
Recommendation
The Switch not working and
LED off
1. The Switch is not
connect to the Main
power
2.
The Switch break
down
1. Check power connections
2. Don’t open up the Switch and
send it for repair.
The Switch LED
illuminating, but cannot
control the ON/OFF
Switch of the load attached
Check if the load connect
into the Switch has its
own ON/OFF switch
Set the ON/OFF switch of the load
attached to ON
The Switch LED
illuminating, but the
Detector cannot control
the Switch
1. Not carry out
association
2. Same frequency
interference
1. Carry out association
2. Wait for a while to re-try
LED keep flashing, but
cannot control
Overload occurs
Remove the load attached or check
max. load cannot exceed
7.5A(Resistive load)
Troubleshooting
Specification
Operating Voltage
100 ~240VAC /50Hz/60Hz
Maximum Load
6.5A(230Vac/120Vac) (Resistive load)
Range
Minimum 40 m in door 100m outdoor line of sight
Operating Temperature 0°C ~ 40°C
Frequency Range
iZOFC22
-1: 868.40MHz; 869.85MHz(EU) /
iZOFC22
-2: 908.40MHz; 916.00MHz(USA/Canada) /
iZOFC22
-3: 922.5MHz/ 923.9MHz/ 926.3MHz (Taiwan/JP)
** Specifications are subject to change and improvement without notice.