23
SECTION 3 - SERVICING
3.12 IGNITION ELECTRODE REPLACEMENT
1.
Refer to Frame 3.8.
2.
Remove the burner. Refer to Frame 3.10.
3.
Unplug the ignition lead from the electrode.
4.
Remove the earth lead from the ignition
electrode.
5.
Remove the 2 screws holding the ignition
electrode to the combustion chamber.
6.
Remove the electrode.
7.
Fit the new ignition electrode, using the
new gasket supplied. Check dimensions
as shown.
8.
Reassemble in reverse order.
9.
Check the operation of the boiler.
Ignition Electrode
3mm
Str
aig
ht
ed
ge
Spark Gap
3.5mm
3.13 FLAME DETECTION ELECTRODE REPLACEMENT
Flame Detection Electrode
12.5mm
Str
aig
ht
ed
ge
1.
Refer to Frame 3.8.
2.
Remove the burner. Refer to Frame 3.10.
3.
Unplug the flame detection lead from the
electrode.
4.
Remove the 2 screws retaining the detection
electrode.
5.
Remove the electrode.
6.
Fit the new flame detection electrode, using the
new gasket supplied.
7.
Reassemble in reverse order.
8.
Check the operation of the boiler.