Mora Temp Duo 72 20 00 Instruction Download Page 2

 

  ON 

ON 

ON 

  ON 

ON 

OFF 

  ON  

OFF 

ON 

  ON 

OFF 

OFF 

  OFF 

ON 

ON 

  OFF 

ON 

OFF 

  OFF 

OFF 

ON 

  OFF 

OFF 

OFF

 

After flush time

1 sec.
2 sec.
3 sec.
4 sec.
5 sec.
6 sec.
7 sec.
8 sec

.

*

* normal setting

Contact  for  connection  of 
battery cassette (red/black 
cable).

 

 

              Distance settings (fin adjust. with screw in box) 

6

 

 

  0 cm - 15 cm 

ON 

 

 

15 cm - 45 cm 

OFF

Max flush time

none

12 sec.

24 sec.

48 sec.

*

  4 

 

ON 

ON 

  ON 

OFF 

  OFF 

ON 

  OFF 

OFF 

Electronics settings:

002K0104

500  OL

(RESET)

1   2   3   4   5   6

CTS   208-6       T946

O

N

A

C

<->D

C

Settings breaker 1-3: After 
flush  time,  4-5:  Maximum 
flush period, 6: Sensor dis-
tance, rough adjustment.

Self-test  of 
electronics.

Contact for connection to 
transformer (extra acces-
sory).

Contact for connection of 
tap sensor eyes.

Contact for connection 
to solenoid valve (blue/
orange cable)

Indication lamp, 
green.

Indication lamp, 
red.

Change-over  switch  
between  battery  and 
mains.  Mode  DC  = 
battery operation.

Name 

MA-nr

      

Control box

 

72 93 43

Circuit board

 

72 93 42

Sensor eyes with cable

 

72 93 18

Valve block

 

72 93 24

Solenoid coil

   

72 93 46

Connection hose

 

70 97 17

Membrane disk

 

72 92 27

Transformer for mains

 

72 92 30

Cable to transformer

 

72 92 29

Angle element G1/2

 

63 04 71

Ball valve 

63 21 51

002K0104

500  OL

(RESET)

1   2   3   4   5   

6

CTS   208-6       

T946

O

N

AC<->DC

Control box

Circuit board

Valve block

Solenoid coil

Membrane disk

Transformer for mains

Sat at 6V on delivery. 
Adjustable to 12V

Cable to transformer

Angle element G1/2

Sensor eyes with cable

Connection hose

Spare Part number

SETTINGS AND CONNECTIONS

+

-

* normal setting

*

SPARE PARTS

Diagram 1

Ball valve

INSTRUCTION

2

  07.04. MA nr 1001032 

Summary of Contents for Temp Duo 72 20 00

Page 1: ...cuit board and put back the cover On AC operation select AC instead of DC on the circuit board reset the transformer to 12V operation Connect to circuit board Press RESET 3 Connect the valve block to the mixer s connection pipe remember the sup port sleeves in the connection pipe and to incoming hot and cold water If the mixer has an outlet for connecting a dishwasher connect the dishwasher s conn...

Page 2: ... tap sensor eyes Contact for connection to solenoid valve blue orange cable Indicationlamp green Indicationlamp red Change over switch between battery and mains Mode DC battery operation Name MA nr Control box 72 93 43 Circuit board 72 93 42 Sensor eyes with cable 72 93 18 Valve block 72 93 24 Solenoid coil 72 93 46 Connection hose 70 97 17 Membrane disk 72 92 27 Transformer for mains 72 92 30 Cab...

Page 3: ...from the hot water side On the hot water side the cold water plug must be fitted included To do this you only need a 3mm Allen key When the plug has been fitted the tap will always give 100 cold water during sensor operation The function of the mixer valve has been totally blocked and the water that the tap now produces during sensor operation can be used as drinking water and for food preparation...

Page 4: ...ew apart the solenoid valve and look for dirt and check the membrane disk Clean and where necessary replace the membrane disk see figure below The tap is dripping The sensor distance is too far Adjust the sensor distance to about 5 cm in front of the sensor eyes The tap opens shuts off con stantly The sensor eyes are defective The sensor distance setting is not reacting Replace the sensor eyes Nor...