Summary of Contents for TRUNKGUARD TPS400

Page 1: ...TPS400 May 2016 206 791 00C TRUNKGUARD Fieldbus Power Supply TRUNKGUARD Fieldbus Power Supply TPS400...

Page 2: ...nections 7 Terminator 7 Grounding 8 Case Ground 8 Shield Ground 8 Surge Ground 8 Recommended Ground Wiring Practices 8 Testing and Troubleshooting 9 LED Operation 9 CE Conformity 10 Operation 10 Maint...

Page 3: ...odules for each segment Modules are hot swappable with load sharing in redundant pairs to maintain power to the segment in the instance that one module in a pair needs to be removed Universal Modules...

Page 4: ...mal ORANGE Out put Voltage 18V LED Short GREEN normal RED Cable Short LED Open GREEN normal RED Carrier Fault FDM252 Fieldbus Diag nostics Module Power Dissipation 0 5W maximum LED Type GREEN Normal R...

Page 5: ...Figure 2 Dimensions for The TRUNKGUARD TPS401 Simplex Dimensions 114mm 4 50in TPS401 4D TPS401 4Y 300mm 8 5in TPS400 121mm 4 75in Figure 3 Dimensions for The TRUNKGUARD TPS402 Duplex 114mm 4 50in 356...

Page 6: ...e on board screws to secure the module to the Carrier Fieldbus Diagnostics Modules are required for alarm indication and alarm contact output but removal or non installation does not affect the power...

Page 7: ...re recommended for use with stranded cable Field side segment wiring is made via screw clamp pluggable terminals marked FIELD HOST connections are made either through the terminals marked HOST or via...

Page 8: ...onnected to the normal SHIELD ground When used for surge protection the shorting bar between these ground points must be removed Therefore if no surge protection is being used this shorting bar must b...

Page 9: ...OISE 2 NOISE 3 NOISE 4 LED Indication GREEN RED OFF Normal Operation Input Voltage A 18V Module failure GREEN RED OFF Normal Operation Input Voltage B 18V Module failure GREEN RED OFF Normal Operation...

Page 10: ...quirements for programmed maintenance TPS400 Series modules contain no user serviceable parts Non functioning units under warranty should be returned to Moore Industries for replacement or repair Moor...

Page 11: ...D 800HSE FDM252 Segment 2 Segment 3 Segment 4 Segment 2 Segment 3 Segment 4 TPS400 Segment 1_1A Fieldbus Cable Fieldbus Cable Fieldbus Cable Control Network HSE Subnet Server AC 800M LD 800HSE LD 800H...

Page 12: ...utilizes Series 2 H1 cards To install TRUNKGUARD with an Emerson DeltaV system refer to Figure A 2 Segment 1_1A Emerson Series 2 H1 Card Series 2 H1 Card FDM252 Segment 2 Segment 3 Segment 4 TPS400 S...

Page 13: ...System Configuration To utilize TRUNKGUARD with a Yokogawa CENTUM system refer to Figure A 3 below AKB336 AKB336 AKB336 FDM252 TPS400 FDM252 Segment 2 Segment 2 Segment 3 Segment 4 Segment 3 Segment...

Page 14: ...the TPS 400 Carrier board Refer to Figure A 4 below FDM252 Segment 2 Segment 3 Segment 4 TPS400 DB37 DB25 Cable DB37 DB25 Cable FDM252 Segment 2 Segment 3 Segment 4 Simplex TPS401 4D Duplex TPS402 4D...

Page 15: ...implex TPS401 4D Duplex TPS402 4D Honeywell Series C FIM 1 2 3 4 SEGMENT 1 SEGMENT 1 Honeywell Series C FIM 1 2 3 4 DB25 16 pin Cable Segments 1 4 Multi Segments with alarm connections P N 804 013 26...

Page 16: ...BREACH OF ANYWARRANTY CONCERNINGTHE GOODS OR SERVICES SHALL BE FOR THE COMPANY AT ITS OPTION TO REPAIR OR REPLACE THE GOODS OR SERVICES OR REFUND THE PURCHASE PRICE THE COMPANY SHALL IN NO EVENT BE L...