background image

CPT

The Interface Solution Experts

PC-Programmable Signal
Isolater/Converter

Table 3.

  Assembling the equipment needed to confi gure the CPT (HLPRG)

Connecting the CPT to the PC

Connect the RS-232 end of the cable to the PC’s COM 
port.

See Table 3 for information on the necessary 
equipment

Installing the Confi guration Software

Refer to Table 3 for the equipment needed.

1. I

nsert the 

Moore Industries Interface Solution 

PC Confi guration Software

 CD into the CD 

drive of the PC.  Access the CD and open the 
“CPA CPT PC Confi guration Software” folder. 

2. 

Double-click the installation program located 
in the folder.  Follow the prompts to correctly 
install the program

.

Once the Confi guration Program is installed on the 
PC,  the CPT can be connected to equipment to 
simulate input and monitor output.  You can then 
change the transmitter’s operating parameters.

No Transmitter  Needed

It is not necessary to connect the transmitter to a PC 
to create confi guration fi les using the software.  The 
Confi guration Program can be run without connecting 
a transmitter, and 

most

 parameters can be set 

without benefi t of input from a CPT.  

This makes it easy to create a set of operating 
parameters, save them to disk, and download them to 
one or more transmitters at a later time.

The CPT 

must

 be connected to the PC in order to: 

trim input, trim output, assign a tag, perform a loop 
test, receive (via download) a confi guration fi le, and 
save the confi guration fi le from the transmitter’s 
memory.

Power Supply

24Vdc, ±10% or 117/230Vac (depending on confi guration)

 

 

       Device  

 

 

             Specifi cations

 

Accurate to ±0.009% of span; e.g., HP Model 3478A

80386-based(or faster) IBM PC, or 100% compatible;
4Mb free RAM; 8Mb recommended; 20Mb free disk space on hard drive 
(More RAM & hard disk space is required for Windows NT, 2000, XP, Vista, or 7)
Microsoft Windows

®

 NT, 2000, XP, Vista, or 7

Internet Explorer 3.0+ 
1 (one) serial port (COM 1, 2, 3, or 4) set to 9600 baud, no parity, 8 data bits, and 
1 stop bit or one available USB port (with optional USB cable)

Version 1.0 or greater, successfully installed to the hard drive

Moore Industries PC 

Confi guration Software

Communication Cable

Current or Voltage Source

Accurate to 0.05% of span for the intended application

Multimeter (optional)

Personal Computer

Part# 803-053-26 or optional USB cable, Part#  208-236-00A

Summary of Contents for CPT HLPRG

Page 1: ...CPTMay 2016 225 708 00 D PC Programmable Signal Isolater Converter All product names are registered trademarks of their respective companies CPT HLPRG PC Programmable Signal Isolater Converter...

Page 2: ...s 6 Configuring the CPT 7 Installing the Configuration Software 8 Connecting the CPT to the PC 8 PC Configuration Software Summary 9 Configuration 10 Output Level if Failure 10 Broken Wire Test Overri...

Page 3: ...Custom Table 16 Installation 17 Mounting the CPT 17 Making the Electrical Connections 17 Recommended Ground Wiring Practices 17 CE Conformity 17 Operation 17 Maintenance 17...

Page 4: ...figuration The output may also be configured to narrower spans from the PC Configuration Program TX Power A transmitter excitation power supply is standard on the CPT HLPRG You may access this at the...

Page 5: ...cal 3W max Power Supply Effect 0 002 of span per 1 of line change Input Impedance 20ohms for current inputs 1 1Mohm for voltage inputs Input Over Range Protection 100mA for current inputs 30Vdc for vo...

Page 6: ...KEY AC DC Power Input ACC DCC Power Input CM Relay Common COM Analog Common GND Ground NOTES 1 Terminal blocks can accomodate 14 22 AWG solid wiring 2 NO CM NC labeling is present only when the unit i...

Page 7: ...igent PC Configuration software The software settings are downloaded to the transmit ter in the form of a Configuration File and stored in the instruments memory You can save a backup copy of the file...

Page 8: ...mitter and most parameters can be set without benefit of input from a CPT This makes it easy to create a set of operating parameters save them to disk and download them to one or more transmitters at...

Page 9: ...ou may enable Start Measurements and Stop Measurements upload your configuration to PC or download your configuration to the unit save your configuration to a file and print out your configuration set...

Page 10: ...3 6mA upscale for voltage outputs limits are 0 5V downscale and 11 0V upscale When a failure is detected the Fail Last feature if enabled holds the last measured value before the failure occurred If t...

Page 11: ...re energized whenever the process input is in an alarm condition These relays de energize when the process input returns to the reset point including any deadband Band Alarm The Band Alarm incorporate...

Page 12: ...verifies that the input from the sensor to the alarm is being interpreted correctly The CPT can trim any point along the scale Note that one point trimming applies an offset to the sensor reading whi...

Page 13: ...grammable Signal Isolater Converter Figure 7 Trimming the CPT HLPRG MULTIMETER OR DCS NO INPUT READY ALARM COM COMPUTER PROGRAMMABLE TRANSMITTER VOLTAGE SOURCE _ CURRENT SOURCE _ _ AC OR DC POWER SUPP...

Page 14: ...es stored click the Output Trim ON 5 Set Status back to Measurements On If selected the User trim values will be used and the manufacturer settings will be nullified Loop Test A Loop Test may be perfo...

Page 15: ...he software 3 Insert a value between 5 and 120sec in the Damping Sec field This is the amount of time it will take for the output to reach 63 of the step output change once the input exceeds the value...

Page 16: ...nts you are to set and insert this value into the Number Of Points line hit Enter This will highlight the number of points you have selected Note To clear the table and start over at any time click Cl...

Page 17: ...ons Please refer to Figure 3 for electrical connections Recommended Ground Wiring Practices Moore Industries recommends the following ground wiring practices Any Moore Industries product in a metal ca...

Page 18: ...nt packing material and carefully pack the equipment in a sturdy shipping contain er 5 Ship the equipment to the Customer Service Department nearest you The returned equipment will be inspected and te...

Reviews: