P
ar
t
2: C
omman
d
s
Moog Animatics SmartMotor™ Developer's Guide, Rev. L
Page 382 of 909
DEFAULT
Default Case for SWITCH Structure
APPLICATION:
Program execution and flow control
DESCRIPTION:
Default for SWITCH program control block
EXECUTION:
Immediate
CONDITIONAL TO:
N/A
LIMITATIONS:
Must reside within a SWITCH and ENDS structure
READ/REPORT:
N/A
WRITE:
N/A
LANGUAGE ACCESS:
N/A
UNITS:
N/A
RANGE OF VALUES:
N/A
TYPICAL VALUES:
N/A
DEFAULT VALUE:
N/A
FIRMWARE VERSION:
5.x and later
COMBITRONIC:
N/A
DETAILED DESCRIPTION:
DEFAULT allows controlled code execution in a SWITCH structure for results that are not
evaluated by CASE. There can only be one DEFAULT statement per SWITCH control block.
DEFAULT is not a valid terminal command. It is only valid within a user program.
In the following example, DEFAULT is used when no CASE can be executed for the value of
"v".
EXAMPLE:
SWITCH
x
CASE
1
(" x = 1 ",#13)
BREAK
CASE
2
(" x = 2 ",#13)
BREAK
CASE
3
(" x = -23 ",#13)
BREAK
DEFAULT
("x IS NOT 1, 2 OR -23",#13)
BREAK
ENDS