11.6.44.5 Error 47-4 (emergency code 6100h)
Cause: Upload of safe PLC application file failed
Suggested steps:
Acknowledge error and try upload again
An error occured at the up-
or download of the safety
programm.
l
Please check the security program.
l
Please check the connection settings of your
safety system in Safe PLC.
l
Please reload or download the safety program
again.
11.6.44.6 Error 47-5 (emergency code 6100h)
Cause: Safety firmware invalid (no firmware or CRC failure)
Suggested steps:
Update of safety firmware required, contact your service provider
Invalid safety firmware.
l
An update of the required safety firmware is
necessary.
l
Please report this error to your service partner.
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
427
11 Alarms & warnings
11.6.45 Error 49: Safety system error
11.6.45.1 Error 49-0 (emergency code 6100h)
Cause: Unknown fatal error in functional safety interface
Suggested steps:
Read additional information, check safety system or wiring and acknowledge
alarm/error
This is probably a software
issue.
l
Please try to switch to a different version of
device firmware.
l
Save your dataset and reset the axis module to
factory setting. See if the error persists, or if it
comes with activating a certain feature.
This is possibly a hardware
issue
If other measures fail to solve the problem, please
replace the servo drive.