11.6.32 Error 33: Internal timing error
11.6.32.1 Error 33-0 (emergency code 5300h)
Cause: ADC task automatically interrupted
Suggested steps:
Please restart device.
Computational load in time-
critical task of axis module is
too high.
l
Please reduce computational load by
removing parameters from mapping.
l
De-activate features of control system or
motion control.
This is probably a software
issue.
l
Please try to switch to a different version of
device firmware.
l
Save your dataset and reset the axis module to
factory setting. See if the error persists, or if it
comes with activating a certain feature.
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
404
11 Alarms & warnings
11.6.32.2 Error 33-1 (emergency code 5300h)
Cause: Control task exceeded scan time
Suggested steps:
Please restart device.
Computational load in time-
critical task of axis module is
too high.
l
Please reduce computational load by
removing parameters from mapping.
l
De-activate features of control system or
motion control.
This is probably a software
issue.
l
Please try to switch to a different version of
device firmware.
l
Save your dataset and reset the axis module to
factory setting. See if the error persists, or if it
comes with activating a certain feature.