8.11.2 Control word for synchronized motion
Bit
Function
PLC function
0-7
Start segment (8-bit value)
-
8-15
Reserved
-
16
Absolute (true) / relative (false) master
relationship
-
17
Absolute (true) / relative (false) master
(CAM) relationship at cam in
-
18
Absolute (true) / relative (false) slave
(CAM) relationship at cam in
-
19-23
Reserved
-
24
Change gear ratio of the electronic gear
online
MCB_
GearRatioChange
25
Disable master calculation
MCB_Cam_
MasterEnable
26
Enable master calculation
MCB_Cam_
MasterEnable
27
Select CAM table
MCB_
CamTableSelect
28
Start Ecam
MCB_CamIn
29
Stop Ecam
MCB_CamOut
30
Start Egear
MCB_GearIn
31
Stop Egear
MCB_GearOut
Table 8.35: Control word ECAM (P 1318[0] - MPRO_ECAM_ControlWord)
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
279
8 Motion profile
8.11.3 Status word for synchronized motion
Bit number
Description
0-7
Actual segment (8-bit value)
8-11
Actual ECAM / EGEAR state machine state (4 Bit value)
l
0: ECAM / EGEAR asynchronous
l
1: ECAM / EGEAR synchronous
l
2: ECAM / EGEAR synchronizing
l
3: ECAM / EGEAR desynchronizing
l
4: ECAM / EGEAR active and waiting for going
asynchronous
l
5: ECAM / EGEAR inactive and waiting for going
synchronous
12-26
Reserved
27
ECAM / EGEAR is active
28
Valid segments chosen
29
Master data are valid
30
Master is initialized
31
Master calculation is active
Table 8.36: ECAM status word (P 1326[0] - MPRO_ECAM_StatusWord)