Once the safety prompt is confirmed, the “Manual mode” window will be enabled,
after which you can select a control mode and configure it for manual operation.
Depending on the control mode you selected, one to four configuration tabs will
appear:
A table with the parameters that are specific to the relevant control mode but
that will only apply when using manual mode (e.g. acceleration,
deceleration, setpoint, speed, etc.)
Homing (
Jog mode, which can be used to move the motor step-by-step in a positive or
negative direction with two different speeds.
Reversing operation, in which the motor can be moved back and forth with
adjustable accelerations and speeds.
MOOG
ID
No.:
CB40859-001
Date:
02/2018
MSD Servo Drive - Device Help
30
3
15 Manual mode
Fig. 15.2: “Manual mode” window (enabled) - Control mode tab