moog
MSD Servo Drive DC-AC Operation Manual
[
]
Electrical
installation
27
Id.-No.: CA97554-001 Date: 06/2012
3.6.2 DC power supply connection
Step
Action
Comment
1.
Make sure all MSD Servo Drives DC-AC are
arranged in a row and abutting each other.
See mounting instructions in sec-
tion 2
2.
For the DC power supply to the
DC-AC
servo
drives use the supplied ready made-up cables.
Interconnect all (+) connections and all (-)
connections via terminals X11.
The supplied ready made-up cables
are as long as the corresponding
device is wide.
3.
For more details on the mains power
connection of the power supply unit refer
to the MSD Power Supply Unit Operation
Manual.
ATTENTION!
•
Connecting cable
Use the supplied ready made-up cables for the electrical connections be-
tween the devices. If extending the DC link is unavoidable, be sure to com-
ply with the rules set out in section B.5 (page 79). If cables not conforming
to the stipulated rules are used, Moog GmbH can provide no guarantee of
stable and safe operation.
•
Terminal cover
The cover over terminal X11 (DC connection) on sizes Size 1 to Size 5 must
be closed after installing the ready made-up cables. Operation without the
cover is not permitted.
NOTE:
Prior to commissioning, the value of the connected supply voltage
must be set in the servo drive. For more details see section 4 "Commission-
ing“.
!
Fig. 3.9 Detail: DC power supply connection, Size 5
Fig. 3.10 Detail: Size 6A DC power supply connection to smaller DC-AC servo drives