MSD Servo Drive AC-AC Operation Manual
moog
62
Id. no.: CA65642-001 Date: 03/2012
A.1.4 Current carrying capacity Size 3 - Size 4, liquid-cooled
NOTE:
The shutdown temperature for liquid-cooled devices is (internally at
the heat sink) +65 °C (+149 °F). The servo drive is shut down and operation
can only be resumed after a short cooling phase.
Servo
drive
Sw
itc
hi
n
g
f
re
-
q
u
en
cy o
f t
h
e
p
o
w
er
st
ag
e
A
m
b
ie
nt
te
m
p
er
at
ur
e
Rated current
Peak current [A
eff
]
at
40
0 V
AC
at 4
60 V
AC
at 4
80 V
AC
with linear in-
creasing rotating
field frequency
0 to 5 Hz
for inter-
mittent
opera-
tion
for
time
1)
[kHz]
[°C]([°F]) [A
eff
] [A
eff
] [A
eff
]
0 Hz
5 Hz
>5 Hz
[s]
G395-016
(Size 3)
4
+40 (+104)
16.0
16.0
16.0
32.0
32.0
32.0
10
8
16.0
13.9
13.3
32.0
32.0
32.0
12
11.0
8.8
8.0
22.0
22.0
22.0
16
8.0
5.9
5.2
16.0
16.0
16.0
G395-020
(Size 3)
4
+40 (+104)
20.0
20.0
20.0
40.0
40.0
40.0
10
8
20.0
17.4
16.6
40.0
40.0
40.0
12
13.8
11.0
10.0
27.6
27.6
27.6
16
10.0
7.4
6.5
20.0
20.0
20.0
G395-024
(Size 4)
4
+40 (+104)
24.0
24.0
24.0
48.0
48.0
48.0
10
8
24.0
21.0
20.0
48.0
48.0
48.0
12
15.8
12.4
11.3
31.6
31.6
31.6
16
11.3
9.2
8.4
22.6
22.6
22.6
G395-032
(Size 4)
4
+40 (+104)
32.0
32.0
32.0
64.0
64.0
64.0
10
8
32.0
28.0
26.7
64.0
64.0
64.0
12
21.0
16.5
15.0
42.0
42.0
42.0
16
15.0
12.2
11.2
30.0
30.0
30.0
Data apply for a motor cable length
≤
10 m.
1) Shut-down according to I²t-characteristic
2) Supply with 400 V
AC
at maximum 70% preload
Table A.4 Rated and peak current Size 3 and Size 4 (liquid-cooled)
A.1.5 Current carrying capacity Size 5 - Size 6A, liquid-cooled
NOTE:
The shutdown temperature for liquid-cooled devices is (internally at
the heat sink) 65 °C (+149 °F). The servo drive is shut down and operation
can only be resumed after a short cooling phase.
Servo
drive
Sw
itc
hi
n
g
f
re
-
q
u
en
cy o
f t
h
e
p
o
w
er
st
ag
e
A
m
b
ie
nt
te
m
p
er
at
ur
e
Rated current
Peak current [A
eff
]
at
40
0 V
AC
at 4
60 V
AC
at 4
80 V
AC
with linear in-
creasing rotating
field frequency
0 to 5 Hz
for inter-
mittent
opera-
tion
for
time
1)
[kHz]
[°C]([°F]) [A
eff
] [A
eff
] [A
eff
]
0 Hz
5 Hz
>5 Hz
[s]
G395-053
(Size 5)
4
+45 (+113)
53
49
48
90
90
90
30
8
53
49
48
90
90
90
12
53
49
48
90
90
90
16
49
45
44
84
84
84
G395-070
(Size 5)
4
+45 (+113)
70
65
63
120
120
120
30
8
70
65
63
120
120
120
12
68
63
61
116
116
116
16
49
45
44
84
84
84
G395-084
(Size 5)
4
+45 (+113)
84
78
76
144
144
144
30
8
84
78
76
144
144
144
12
68
63
61
116
116
116
16
49
45
44
84
84
84
Data apply for a motor cable length
≤
10 m
1) Shut-down according to I²t-characteristic
2) Supply with 400 V
AC
at maximum 70% preload
Table A.5 Rated and peak current Size 5 to Size 6A (liquid-cooled)