© MOOG 2019
This document is subject to MOOG INTELLECTUAL AND PROPRIETARY INFORMATION LEGEND . The details are on page II.
41
MRJ06301
Full
Next, press
“TOOLONG” located at the lower right of the screen to set the core to the closed state (Tooling
position). Set the core position by TOOLING on the F2 screen. (*When the core reaches the tooling posi-
tion, the TOOLING key will return from yellow to white.If you
press the TOOLING key again while moving to the tooling
position, the TOOLING key will return to white and the core
stops) Fill the accumulator using the host controller. Move
the accumulator to the fully filled position (the state where
the molten plastic is stored in the maximum amount). This
is the [Full] position. While Full is highlighted, press the
[SET] key when the accumulator is in the full fill position.
The filling position is saved and [End of Filling] in the status
monitoring area lights up. Highlight moves to [Filling Type].
Figure 1-47 FULL Accumulator Set Up
The Empty and Full value cannot set same value, it is automatically set 0.2V space, if set
same value e.g, Empty=5V and Full=5V, then automatically Empty set 4.8V.
And these two values can set only 0 to 1
0V. If set both 0V, value of “Full” change to 0.2V.
And, if set both 10V, value of “Empty” change to 9.8V automatically.
Filling type
Next, decide Filling Type. Filling Type is the relationship between "Empty" and "Full" positions when the
vertical axis (Profile Points number) on the profile data is set to "shot size" (refer to 2-4-2. F1: Profile
mode) .
Extrusion
Plastic extrusion to the container mold
starts at the filled Accumulator posi-
tion determined by the sum of Cush-
ion, Shot size and Delay when Filling
type - Extrusion is selected. End of
extrusion is the Cushion position.
” End of filling position is the
Shot size stroke plus Delay stroke
plus the Cushion strok
Figure 1-48 Extrusion Fixed
Filling
Plastic extrusion to the container
mold starts at the Accumulator
filled position (End of Filling) when
FILLING FIXED is selected. The
length of stroke is determined by
the sum of SHOT SIZE plus DE-
LAY. (Figure 1-49)
Select either EXTRUSION FIXED
or FILLING FIXED and press SET
Figure 1-49 Filling Fixed