3 Product Description
Nameplate
© Moog GmbH User Manual "D633-A Series" (CA80942-001; Version 1.0, 12/08) 20
3.5.2.2 Rated flow identification
Rated flow identification
(2nd position in type
designation)
The rated flow identification, i.e., the 2nd position in the valve type designation,
indicates the rated flow of the valve.
Overview of type designation:
Chapter "3.5 Nameplate", page 18
3.5.2.3 Maximum pressure identification
Maximum pressure
identification
(3rd position in type
designation)
The maximum pressure identification, i.e., the 3rd position in the valve type
designation, indicates what maximum operating pressure is permissible.
Overview of type designation:
Chapter "3.5 Nameplate", page 18
Type designation:
1
2
3
4
5
6
7
8
9 10
A
• •
K
•
5
•
•
•
•
•
Rated flow Q
N
at
Ident.
∆
p
N
= 35 bar (508 psi)
∆
p
N
= 5 bar (72.5 psi)
02
5 l/min (1.3 gpm)
2 l/min (0.53 gpm)
04
10 l/min (2.6 gpm)
4 l/min (1.0 gpm)
08
20 l/min (5.3 gpm)
8 l/min (2.1 gpm)
16
40 l/min (10.5 gpm)
16 l/min (4.2 gpm)
Table 6: Rated flow identification in the type designation
rated flow identification
Type designation:
1
2
3
4
5
6
7
8
9 10
A
• •
K
•
5
•
•
•
•
•
Ident.
Maximum operating pressure
K
350 bar (5,075 psi)
Table 7: Maximum pressure identification in the type designation
maximum pressure identification