Moog ACV with CANopen bus interface
7 Servo valve functions
Pressure controller
B99224-DV018-D-211, Rev. A, October 2018
176
7.5.13.1 Object 0x2305[N]: Integrator gain
This parameter contains the integrator gain.
7.5.13.2 Object 0x2306[N]: Integrator factor
This parameter contains an additional factor which is multiplied to the integrator gain if the control error is
larger than the <IntegratorControlRange>.
7.5.13.3 Object 0x2307[N]: Integrator control range
This parameter contains the range of the control deviation for the integrator part. If the control deviation is out-
side the range, the <IntegratorGain> is multiplied with the <IntegratorFactor> (which is zero by default).
7.5.13.4 Object 0x231D: Integrator gain status
This parameter shows the state of the switch whether the <IntegratorFactor> (0x2306) is multiplied (value = 2)
or not (value = 1).
ValvePressureControl
Index
Sub-index
Parameter name
Data type
Access
Per-
sis-
tence
Value range
Default
0x2305
N=1…16
IntegratorGain
FLOAT32
rw
Y
0.0…+inf
0.0
ValvePressureControl
Index
Sub-index
Parameter name
Data type
Access
Per-
sis-
tence
Value range
Default
0x2306
N=1…16
IntegratorFactor
FLOAT32
rw
Y
0.0…+inf
0.1
ValvePressureControl
Index
Sub-index
Parameter name
Data type
Access
Per-
sis-
tence
Value range
Default
0x2307
N=1…16
IntegratorControlRange
INT16
rw
Y
0…16384
163
ValvePressureControl
Index
Sub-index
Parameter name
Data type
Access
Per-
sis-
tence
Value range
Default
0x231D
0
IntegratorGainStatus
UINT8
r
Y
1…2
1