- 3 -
Figure 8
CAMERA FOCUSING (Figure 8)
1.
The camera is factory equipped with a 3.6mm fi xed lens. A
2.5mm lens is also provided. To remove the 3.6mm lens, loosen
the set screw and unscrew the lens counter-clockwise.
2.
Fine focusing of the lens: Loosen the set screw in the lens mount
and manually rotate the lens until a clear picture is achieved. Once
the focus is set, retighten the set screw.
Set screw
Fixed lens
CAMERA SETTINGS
SERIAL NUMBERS BEGINNING WITH YK
FIXED AND FIXED VARI-FOCAL LENSES. There are no user
adjustable settings on these units (Figure 9).
Figure 9
BW Fixed and Vari-Focal
NOTE:
To determine which camera is used in your unit, locate the
serial number on the inside of the housing. Match the two
letter prefi x with the corresponding instructions included
here for adjustments.
The operational settings for the camera are defi ned by ten dip
switches located on the PC Board (Figure 9). Moving the switches to
the on position will activate each setting. Factory defaults are pictured
below (Figure 10).
Figure 10
Hi-Res Color, Fixed and Vari-focal fi xed lenses
Dip Switches
Auto Iris
adjustment
screw
DO NOT
ADJUST
Factory
Use Only
Connection to
Power Board
SERIAL NUMBERS BEGINNING WITH MC
FACTORY DEFAULT FIXED AND FIXED VARI-FOCAL LENSES:
Dip Switches 5 and 7 on, all others off.
Figure 11
NOTE: Dip switches are factory pre-set for optimum performance.
In certain
specifi c
instances it may be necessary to adjust
one or more settings. Consult a qualifi ed technician before
making any adjustments
.
A Dip Switch settings chart is