- 2 -

CAMERA FOCUSING

1

.

  Fine focusing:

     Fixed Lens:  Loosen the set screw in the lens mount and 

     manually rotate the lens until a clear picture is achieved. Once 

     the focus is set, retighten the set screw (Figure 5).

Figure 5

Set screw

Fixed  lens

Vari-Focal Lens:  First, adjust the Magnification Lock Screw to the 

desired magnification (telephoto to wide angle).  Tighten the Lock 

Screw.  Next, adjust the Focus Lock Screw until a clear picture is 

achieved.  Tighten the Lock Screw (Figure 6).

Figure 6

Magnification lock screw

Focus lock screw

Fixed iris vari-
focal lens

CAMERA ADJUSTMENTS

1. After completing installation of the housing, use the segmented
    arms to adjust each camera to the desired viewing location
    (Figure 4). 

2. Once camera adjustments are made, place the dome back into
    position to be sure cameras are not touching the inside of the 
    dome. If any do, adjust until they are clear. 

  

Figure 4

WIRING

1.  Make the proper connections to the incoming power. The RED 
     wire is POSITIVE (+), the BLACK wre is NEGATIVE (-) (For refer-
     ence purposes. Polarity is not important in this unit). The GREEN
     wire, labeled Ground, is GROUND for VAC or VDC connections. 
     NOTE: Connect green ground wire to earth ground (metal conduit,
                 metal stud, etc.)

2.  Attach the BNC connectors to the video in.

Auto Iris Lens:  

NOTE:  THE AUTO IRIS LENS IS SET AT THE FACTORY. 

             • IF YOU EXPERIENCE VIDEO TOO LIGHT OR DARK 

               AUTO IRIS ADJUSTMENT MAY BE NEEDED.

             

 SEE THE TROUBLESHOOTING SECTION FOR 

             ADJUSTMENT INFORMATION.

CAMERA SETTINGS

SERIAL NUMBERS BEGINNING WITH YK

FIXED AND FIXED VARI-FOCAL LENSES. There are no user 

adjustable settings on these units (Figure 7).

Figure 7

AUTO IRIS LENSES. The dip switches are factory set with AES 

off and backlight compensation on (Figure 8). The auto iris is also 

set at the factory, but an adjustment screw is included for use if 
needed. See page 10 for instructions on adjusting Auto Iris.

Auto Iris
adjustment 
screw

AES Default Off

Backlight 
Compensation 
Default On

Figure 8

BW Fixed and Vari-Focal

BW Auto Iris

NOTE:

 To determine which camera is used in your unit, locate the 

            serial number on the inside of the housing. Match the two 
            letter prefix with the corresponding instructions included 
            here for adjustments.

Summary of Contents for QMRC Series

Page 1: ...EVISION DATE July 6 2004 81 IN5258 07064 QMR Ceiling Mount Dome QMR T C X XXXX Figure 1 Figure 2 7 With the bottom flange pressed up against the ceiling rotate the support arms to the outside the arms will fall to the back side of the ceiling Tighten the 3 support arm screws Figure 2 8 If the housing is going into a ceiling where the support arms will not work secure the housing by running bolts in...

Page 2: ...IVE For refer ence purposes Polarity is not important in this unit The GREEN wire labeled Ground is GROUND for VAC or VDC connections NOTE Connect green ground wire to earth ground metal conduit metal stud etc 2 Attach the BNC connectors to the video in Auto Iris Lens NOTE THE AUTO IRIS LENS IS SET AT THE FACTORY IF YOU EXPERIENCE VIDEO TOO LIGHT OR DARK AUTO IRIS ADJUSTMENT MAY BE NEEDED SEE THE ...

Page 3: ...is in the on position the auto iris lens controls the amount of light on the chip If in the off position the light level is controlled electronically Used to help improve the color quality of the camera picture under different light ing conditions The Fac tory Default is Switch 7 ON switches 6 and 8 OFF NOTE ANY ADJUSTMENTS TO THESE SETTINGS SHOULD ONLY BE MADE BY A QUALIFIED CCTV TECHNICIAN See e...

Page 4: ...nnecting the receiver end of the the unshielded twisted pair cable will be included with the NVT receiver Following are instructions for connecting the unshielded twisted pair cables to the RJ45 Cat 5 cable running outside your housing UNSHIELDED TWISTED PAIR VIDEO WIRING 1 Video for all four cameras is contained in the one RJ45 Cat 5 cable An RJ45 female coupling is provided so that all connectio...

Page 5: ...point Unshielded Twisted Pair wire gauge 24 or thicker stranded or solid Category 2 3 4 or 5 2 The video signal may co exist in the same wire bundle as other video telephone data control signals or low voltage power It is also OK to run NVT video signals in or near electromagnetic fields in accordance with National Electrical Code local or other local safety requirements 3 DO measure the wire dist...

Page 6: ...2525 Park Central Blvd Decatur Ga 30035 770 987 7550 800 554 1124 Fax 770 987 9705 800 826 0366 www videolarm com 1 2 4 3 5 MR7 Exploded Diagram and Replacement Parts List ...

Page 7: ...ED BRACKET 5 RPQF20NF3 HI RES B W 3 6 FIXED LENS RPQF20NA HI RES B W 4 9MM AUTO IRIS VARIFOCAL RPQF50NF3 HI RES COLOR 3 6 FIXED LENS RPQF50NA HI RES COLOR 4 9MM AUTO IRIS VARIFOCAL RPQF70NA HI RES DAY NIGHT 4 9MM AUTO IRIS VARIFOCAL N S RPQMR01 PACKET ASSEMBLY 6 RPMR7050 WHITE TRIM RING ASSEMBLY 7 RCMR7C CLEAR REPLACEMENT CAPSULE MR7 RCMR7T TINTED REPLACEMENT CAPSULE MR7 8 RPQD08 SET OF 4 SPACERS ...

Page 8: ... charges The limited warranty stated in these product instructions is subject to all of the following terms and conditions 1 NOTIFICATION OF CLAIMS WARRANTY SERVICE If Purchaser believes that the Product is defective in material or workmanship then written notice with an explanation of the claim shall be given promptly by Purchaser to Videolarm but all claims for warranty service must be made with...

Page 9: ...NES ON SCREEN PICTURE IS CLEAR LOW OR NO COLOR PICTURE IS DARK OR GRAINY IN GOOD LIGHTING CONDITIONS The auto iris lens is set at the factory If you experience video too light or dark you can manually adjust using the auto iris adjustment screw If there is low or no color the Auto Iris is too open if the picture is dark or grainy in good conditions the Auto Iris is too closed To adjust the auto ir...

Page 10: ...eck polarity WON T SYNC TORN PICTURE 1 Make sure that you are using unshielded twisted pair wire 2 Check distance equalization settings 3 For installations with passive non amplified transceivers at both ends check for ground loops This may be done with an AC Voltmeter as shown below If the voltage is greater than 1 2 volt use an amplified receiver such as the NV 652R NV 862R or NV 1662R Alternate...

Page 11: ... LOAD POWER SUPPLY 24 AWG 22 AWG 18 AWG 16 AWG 1 2 5W 24 VAC VDC 1718 523 2733 833 6909 2106 10985 3348 2 5W 24 VAC VC 834 254 1327 404 3356 1023 5335 1626 3 7 9W 24 VAC VDC 529 161 842 256 2129 649 3385 1032 4 10 9W 24 VAC VDC 359 109 572 174 1447 441 2300 701 NOTE The above table is based on a worst case power supply Using a regulated or switching power supply can increase your cable distance Vi...