Moog Videolarm QMRC Series Product Instructions Download Page 1

Mounting Holes

Support Arm Holes

Support Arms Rotate Out

Support Wires

4.  Remove the trim ring/dome assembly by pulling on the outside 
     of the trim ring.  The ring and dome are connected by three flat    
     springs, which press against the side of the housing and lock into 
     (3) cutouts.
5.  Run electrical cable and video leads into the housing through the 
     conduit knock-out.
6.  With the (3) support arms rotated to the inside, slide the housing
     into the pre-cut hole (Figure 1). 

CAMERAS     VOLTAGE           CURRENT       POWER
        1              24 VAC/VDC     102mA              2.5W
        2              24 VAC/VDC      210mA             5W
        3              24 VAC/VDC      331mA             7.9W
        4              24 VAC/VDC      487mA             10.9W

Use the formula below to select the correct power supply for 
cameras connected in parallel (positive to positive, negative to 
negative):

Total current for a 24 VAC system:

TOTAL CURRENT = (202mA x total number of cameras)

                                  

Note: 202mA is camera plus power supply 

CABLE AND POWER GUIDELINES (Detailed info on Page 11)

This chart shows the proper current needed for power supplies for 
Q-View™ cameras. Use Class 2 Power only. Input voltage must 
be 24 VAC/VDC.

PRODUCT INSTRUCTIONS

REVISION DATE:  July 6, 2004

81-IN5258-07064

QMR Ceiling Mount Dome 

QMR(T/C)X-XXXX

Figure 1

Figure 2

7.  With the bottom flange pressed up against the ceiling, rotate the
     support arms to the outside, the arms will fall to the back side of
     the ceiling. Tighten the (3) support arm screws (Figure 2).

8.  If the housing is going into a ceiling where the support arms will
     not work, secure the housing by running bolts into the solid ceiling
     through the mounting holes in the bottom flange (Figure 1).
9.  For added support, run support wires from a secure structure to
     the two slots provided on the top of the housing (Figure 3).

HOUSING INSTALLATION

 

1.  Carefully remove all equipment from the box.
2.  Place the 11 1/8" template provided with the unit at the desired 
     location on the ceiling. Trace around the template, then cut a hole 
     in the ceiling following the trace lines.  
 3. Remove the desired conduit knock-out from the top of the QMR 
     housing.

Figure 3

TABLE OF CONTENTS

Cable and Power Guidelines   

1, 11

Electrical Specifications 

 

1

Housing Installation 

 

1

Wiring 

 

2

Camera Adjustment 

 

2

Camera Focusing 

 

2

Camera Settings 

 

     Black/White 

 

2

     Color 

 

3

Completion of Installation 

 

3

NVT Instructions 

 

3

Exploded View 

 

5

Warranty Information 

 

6

Service and Safeguard Information  7

Troubleshooting 

 

8

Summary of Contents for QMRC Series

Page 1: ...EVISION DATE July 6 2004 81 IN5258 07064 QMR Ceiling Mount Dome QMR T C X XXXX Figure 1 Figure 2 7 With the bottom flange pressed up against the ceiling rotate the support arms to the outside the arms will fall to the back side of the ceiling Tighten the 3 support arm screws Figure 2 8 If the housing is going into a ceiling where the support arms will not work secure the housing by running bolts in...

Page 2: ...IVE For refer ence purposes Polarity is not important in this unit The GREEN wire labeled Ground is GROUND for VAC or VDC connections NOTE Connect green ground wire to earth ground metal conduit metal stud etc 2 Attach the BNC connectors to the video in Auto Iris Lens NOTE THE AUTO IRIS LENS IS SET AT THE FACTORY IF YOU EXPERIENCE VIDEO TOO LIGHT OR DARK AUTO IRIS ADJUSTMENT MAY BE NEEDED SEE THE ...

Page 3: ...is in the on position the auto iris lens controls the amount of light on the chip If in the off position the light level is controlled electronically Used to help improve the color quality of the camera picture under different light ing conditions The Fac tory Default is Switch 7 ON switches 6 and 8 OFF NOTE ANY ADJUSTMENTS TO THESE SETTINGS SHOULD ONLY BE MADE BY A QUALIFIED CCTV TECHNICIAN See e...

Page 4: ...nnecting the receiver end of the the unshielded twisted pair cable will be included with the NVT receiver Following are instructions for connecting the unshielded twisted pair cables to the RJ45 Cat 5 cable running outside your housing UNSHIELDED TWISTED PAIR VIDEO WIRING 1 Video for all four cameras is contained in the one RJ45 Cat 5 cable An RJ45 female coupling is provided so that all connectio...

Page 5: ...point Unshielded Twisted Pair wire gauge 24 or thicker stranded or solid Category 2 3 4 or 5 2 The video signal may co exist in the same wire bundle as other video telephone data control signals or low voltage power It is also OK to run NVT video signals in or near electromagnetic fields in accordance with National Electrical Code local or other local safety requirements 3 DO measure the wire dist...

Page 6: ...2525 Park Central Blvd Decatur Ga 30035 770 987 7550 800 554 1124 Fax 770 987 9705 800 826 0366 www videolarm com 1 2 4 3 5 MR7 Exploded Diagram and Replacement Parts List ...

Page 7: ...ED BRACKET 5 RPQF20NF3 HI RES B W 3 6 FIXED LENS RPQF20NA HI RES B W 4 9MM AUTO IRIS VARIFOCAL RPQF50NF3 HI RES COLOR 3 6 FIXED LENS RPQF50NA HI RES COLOR 4 9MM AUTO IRIS VARIFOCAL RPQF70NA HI RES DAY NIGHT 4 9MM AUTO IRIS VARIFOCAL N S RPQMR01 PACKET ASSEMBLY 6 RPMR7050 WHITE TRIM RING ASSEMBLY 7 RCMR7C CLEAR REPLACEMENT CAPSULE MR7 RCMR7T TINTED REPLACEMENT CAPSULE MR7 8 RPQD08 SET OF 4 SPACERS ...

Page 8: ... charges The limited warranty stated in these product instructions is subject to all of the following terms and conditions 1 NOTIFICATION OF CLAIMS WARRANTY SERVICE If Purchaser believes that the Product is defective in material or workmanship then written notice with an explanation of the claim shall be given promptly by Purchaser to Videolarm but all claims for warranty service must be made with...

Page 9: ...NES ON SCREEN PICTURE IS CLEAR LOW OR NO COLOR PICTURE IS DARK OR GRAINY IN GOOD LIGHTING CONDITIONS The auto iris lens is set at the factory If you experience video too light or dark you can manually adjust using the auto iris adjustment screw If there is low or no color the Auto Iris is too open if the picture is dark or grainy in good conditions the Auto Iris is too closed To adjust the auto ir...

Page 10: ...eck polarity WON T SYNC TORN PICTURE 1 Make sure that you are using unshielded twisted pair wire 2 Check distance equalization settings 3 For installations with passive non amplified transceivers at both ends check for ground loops This may be done with an AC Voltmeter as shown below If the voltage is greater than 1 2 volt use an amplified receiver such as the NV 652R NV 862R or NV 1662R Alternate...

Page 11: ... LOAD POWER SUPPLY 24 AWG 22 AWG 18 AWG 16 AWG 1 2 5W 24 VAC VDC 1718 523 2733 833 6909 2106 10985 3348 2 5W 24 VAC VC 834 254 1327 404 3356 1023 5335 1626 3 7 9W 24 VAC VDC 529 161 842 256 2129 649 3385 1032 4 10 9W 24 VAC VDC 359 109 572 174 1447 441 2300 701 NOTE The above table is based on a worst case power supply Using a regulated or switching power supply can increase your cable distance Vi...

Reviews: