![Montracon SanuControl Manual Download Page 18](http://html1.mh-extra.com/html/montracon/sanucontrol/sanucontrol_manual_1831069018.webp)
ATTENTION
●
Please ensure the deck is regularly checked for signs of wear
●
Ensure there are no obstructions that would prevent / hinder the decks operation
●
Do not operate as a passenger lift.
●
When lowering the deck please pay attention there are no crushing hazards
●
Do not operated the system on a voltage of less than 22v DC
●
The system (plc) will not allow deck operation if the voltage is less than 18 volts.
●
When operating the deck please always pay attention to the locks and ensure all
locks are retracted when the deck is moving
●
The system is not designed for continuous running!
●
Maximum advised duty is
XXX
per hour.
Summary of Contents for SanuControl
Page 1: ...Montracon Trailers SanuControl Double Deck Manual December 2015...
Page 5: ......
Page 12: ...The switches have covers fitted for protection...
Page 22: ...7 General Arrangement of the System...
Page 23: ...8 Motor Relay Logic...
Page 25: ...Main ve taken from the ve on the motor solenoid...
Page 29: ...10 Hydraulic system The following shows the hydraulic system layout...