The following components and associated Montigo part numbers are for
installation of a roof or wall mounted Power Vent. Only use Montigo Vent
Components. Use of non-Montigo parts will VOID the warranty and may
impede operation of the fireplace.
A - Termination
PVHEX510-300 Wall Mount
5'/10'
PVHFL510-300 Flush Wall
Mount 5'/10'
PVVEX510-300 Roof Mount
5'/10'
B - Frame Kits
EPVRRF (Roof Mount 5"/10")
EPVRWF (Wall Mount 5"/10")
C - Flex Sections
RFL1 (12" f/f Section)
RFL2 (24" f/f Section)
RFL3 (36" f/f Section)
RFL4 (48" f/f Section)
RFL6 (72" f/f Section)
D - Rigid Sections
RXT - 10 (10" f/f Section)
RXT - 20 (20" f/f Section)
REXT - 1 (12" f/m Section)
REXT - 2 (24" f/m Section)
REXT - 3 (36" f/m Section)
REXT - 4 (48" f/m Section)
REXT - 6 (72" f/m Section)
E - Elbows
REL-90MM (m/m 90º Elbow)
REL-90FF ( f/f 90º Elbow)
REL-90FM ( f/m 90º Elbow)
REL-45FM ( f/m 45º Elbow)
F - Support Ring & Plate RSPXT-10
G - Firestop
FS-10
H - Heat Shield
RHS102
Connection and installation of the vent components
should adhere to the following guidelines:
Montigo recommends the use of a flex section for the final pipe
connected directly to the fireplace offering greater flexibility
of installation and absorption of movement�
Firestops must be installed as required by National & local
codes�
Montigo recommends that all exterior corners and joints be
sealed with exterior caulking� However, we encourage you
to consult your Building Envelope Engineer or Waterproofing
Consultant for further recommendations�
Use any combination of rigid and flex pipe as required and in
any orientation (Male connectors can face in any direction)�
Flex sections may be stretched up to 50% of their total length
(e�g� a 24” section maybe stretched to 36”)�
Ensure the pipe ends male to female slide in a minimum of
1 1/2” of overlap.
Connect all vent sections using a minimum of three sheet
metal screws on the outer pipe flue.
Ensure all horizontal runs are supported with a minimum of
3 supports per 10’ of venting�
When hanging/ supporting venting, ensure that 1” clearance
is maintained on sides and bottom of vent runs and 2” above
horizontal vent runs to any combustible material�
Rigid pipe may be cut less than half way from the
female
end only�
Ensure when cutting sections of rigid pipe to maintain integrity
of internal supports�
Place the springs, supplied with the pipe kit, between the
outer and inner pipes to keep the pipes separate and avoid
any possible hot spots�
IMPORTANT:
Please Refer to your Building Envelope
Engineer or Waterproofing Consultant
for a review of ALL penetrations through
exterior walls or the roof�
R720 & R820 Power Vent Indoor Gas Fireplace
Page 21
XG0772 - 150105�4
Installation
Section 3-4: Venting components