background image

Page 9 of 13

MW38-BV  Modular Fireplace

XG0310 Rev. 01 - 11/98

For Your Safety - READ BEFORE LIGHTING:

To Turn Off Gas To Appliance:

Lighting Instructions:

If you cannot reach your gas supplier, call the Fire
Department.

C.

Use only your hand to push in or turn the gas control knob.
Never use tools. If  the knob will not push in or turn by
hand, don't try to repair it, call a qualified service
technician. Force or attempt to repair may result in a fire or
explosion.

D.

Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system,
and any gas control which has been under water.

A.

This appliance is equipped with an ignition system that
lights the pilot burner automatically. 

Do not attempt to

light the pilot by hand.

B. BEFORE LIGHTING

 smell all around the appliance area

for gas.  Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.

What To Do If You Smell Gas:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any
phone in your building.

Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.

1.

Turn off remote switch.

2.

Flip down lower brass trim.

3.

Turn the switch on the gas control to "Off".

4.

Flip up brass trim.

1. STOP!  

Read the safety information above on this label.

2.

Flip down lower brass trims.

3.

Turn switch on the gas control to OFF".

4.

Wait 5 minutes to clear out any gas.  If you smell gas,

STOP! 

Follow "B" in the safety information above on this

label.  If you don't smell gas, go to the next step.

5.

Turn switch on the gas control to "ON".

 NOTE:

 This unit is

equipped with an ignition system that lights the pilot burner

automatically. 

Do not attempt to light the pilot by hand.

6.

Turn on wall switch.

7.

Flip up lower brass trim.

8.

If the fireplace does not operate, follow the instructions "To

Turn Off Gas To Appliance" and call your service technician

or gas supplier.

with Honeywell  Intermittent  Pilot

WARNING:

If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.

Operation -  Model MW38-BV-I

MW38-BV-I

Gas

Inlet

Gas Control Switch
Shown in "On" Position

Summary of Contents for MW38-BV

Page 1: ...in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Warning Improper insta...

Page 2: ...ons If the optional air circulating fan kit is installed it must be electrically grounded in accordance with CSA C22 1 Canadian Electrical Code Part 1 and or Local Codes Installations in the USA must...

Page 3: ...rd clearance as specified by the manufacturer of the B Vent 14 33 41 35 38 28 35 14 4 4 Figure 1 Fireplace dimensions Figure 2 Framing dimensions When sheetrock is not used behind the fireplace framin...

Page 4: ...may be connected to a wall switch The valve generates its own power on a millivolt circuit Use only low voltage wire and DO NOT connect any external power to it Refer to Figure 26 for wiring requireme...

Page 5: ...he effects of elevated mantel temperatures which may be in excess of product design for example candles plastic or pictures This can cause melting deformation discoloration or premature failure of T V...

Page 6: ...normal occurance Gas Control and Pilot Wiring MW38 BV I Honeywell Q3450 Pilot Assembly Pilot Electrical Harness Connector Honeywell Gas Control SV9501M Gas Control Connector Fuse Limit Switch Wall Swi...

Page 7: ...ess you may remove the effiiciency baffles to gain access to the venting plate 3 Remove the insert by tipping the top of the insert outward and lifting the tabs past the slots in the bottom of the she...

Page 8: ...Model MW38 BV 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up lower brass trim 1 Turn off remote switch 2 Flip down lower brass trim 1 STOP Read the safety inform...

Page 9: ...o light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn...

Page 10: ...water Operation Lighting Instructions See pages 8 and 9 Burner Adjustment The Wildfire is equipped with an adjustable burner allowing you to raise or lower the flames To adjust the flames locate the...

Page 11: ...ve open Replace SV9500 SV9600 Check Transformer Line Volt Supply Replace SV9500 SV9600 Save old Igniter Flame Rod Assembly for service INSET HSI Terminals CHECK Line voltage power Low voltage transfor...

Page 12: ...other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability Limitations On Liability Limitations On Liability...

Page 13: ...el MW38 BV I 6 Aluminum Tubing 1 4 dia 7 Locking Nuts 8 Spacer 9 Bulkhead Fitting 10 90 Elbow 11 Burner Orifice 12 Burner Tube Available Options and Accessories 13 Add on Bay Window 14 Hand Held Remot...