P/N XG0634
M38DV-ST (MH) Gas Conversion Kit
Gas Conversion Instructions
Pilot Assembly:
Ember Burner:
3. Disconnect the 1/4" tubing from the fitting on the underside of
the pan base. Disconnect the fitting from the inlet side of the gas
control valve.
4. Spin off the coupling just above the tee. The gas valve assembly
will drop out of the way, allowing access to the coupling.
5. Uncrew the coupling assembly from the pan base. The orifice is
located at top end of coupling. Unscrew it and install the orifice
from the package marked 'Ember Burner Orifice' in this kit to
convert to the new gas.
Main Gas Control Regulator:
6. Before re-assembling the gas tubing, the gas valve must be
converted to operate on the new gas. Change the regulator on
the SIT Nova gas valve.
Note: This fireplace has a flip-over regulator, and needs no extra
parts to convert.
7. To convert from one gas to another, simply unscrew the regula-
tor, turn over and reinstall. One face of regulator is stamped NG,
the other is marked LPG. The outer face of screw will indicate
the correct gas.
8. Reassemble the gas fittings.
Figure 3.
The Pilot Assembly.
Figure 4.
The Pilot Assembly, with cap off. The pilot hood will snap
off; the orifice must be removed with an allen key.
CAUTION - Before you begin:
1. Shut off gas at the shut-off valve and disconnect the electrical
supply (if used).
2. Remove the glass door as shown in the installation instruc-
tions
and remove the logs. Flip down the lower trims to access the
A. Conversion
Figure 1b.
Changing the ember burner orifice.
Figure 1a.
Accessing the ember burner orifice.
9. Remove pilot hood/ orifice cap by pulling it off the pilot assembly.
The cap will snap off with slight pressure; the orifice must be
removed with an allen key.
(See Figure 4)
10. Install the new orifice from the package marked 'Pilot Orifice' in
this kit to convert to the pilot to the new gas. Tighten the orifice
securely with an allen key. Re-attach the pilot hood, making sure
the notch in the hood lines up with the tab on the pilot assembly.
Figure 2.
Sit 820 Convertible Valve.