M38DV-PFC Peninsula Gas Fireplace

Appendix A - Spare Parts

1

3

4

5

6

Model M38DV-
PFC-I

Model M38DV-PFC

5/16 A lum.
Tubing

PSE

5/16 A lum.
Tubing

2

7

1.  Fan Motor (MBL-1)
2.  Power Cord (PPCH-4)
3.  Stucco Frame (MSR)
4.  Stucco Frame (MOSR)
5.  Brick Frame (BSR)

6.  Termination (PTKO Series)
7.  Heat Guard (PTKOG)
8.  Horizontal Trim Kits
9.  Peninsula 5-Piece Fibre Logset

8

9

Summary of Contents for M38DV-PFC

Page 1: ...rviceormaintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier For Your Safety Do not store or use gasoline or other flam mable vapors and liq uids in the vicinity of this or any other appliance Peninsula Direct Vented Gas Fireplace M38DV PFC Installer Leave this manual with the a...

Page 2: ...r Installations in Canada must conform to the current CAN CGA B 149 1 and 2 Gas Installation Code and local regulations This fire place s fans must be electrically grounded in accordance with CSA C22 1 Canadian Electrical Code Part 1 and or Local Codes Installations in the USA must conform to local codes or in the absense of local codes to the National Fuel Gas Code ANSI Z223 1 1988 The fans must ...

Page 3: ...on against freezing temperatures it is recommended that outer walls of the chase be insulated with a vapour barrier This will reduce the possibility of a cold air convection current on the fireplace End View WARNING When this appliance is installed directly on carpeting tile or any combustible material other than wood flooring it must be installed on a metal or wood panel extending the full width ...

Page 4: ...d from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Installation Vent Installation This section covers the installation of direct venting and terminations For a detailed diagram of allowed termination locations see Appen dix B Installation Requirements...

Page 5: ...s required Use the vent graph below to determine an acceptable vent run Unacceptable venting can affect the fireplace s combustion the maximum horizontal vent run is 16 feet The Venting Graph Measure the vertical height from the fireplace hearth to the centre of the termination and the horizontal run from the from the fireplace flue collar to the wall flange of the termination Plot on the Venting ...

Page 6: ...le A 10 section and elbow PIHR 10 used in conjunction with 3 ft flex section PFL 3 will when extended in a chase allow for a maximum horizontal run of twelve and one half feet from the centre of the fireplace to outside wall and a minimum of 7 6 when retracted in op posite direction See Figure 9 D flex sections and E solid sections may be used in conjunction with one another to obtain different po...

Page 7: ...tion PFL 2 24 section PFL 3 36 section PFL 4 48 section C Solid sections PEXT 1 12 section PEXT 2 24 section PEXT 3 36 section PEXT 4 48 section PEXT 6 72 Section D Support Ring Plate PSPXT 7 8 dia E Firestop PS 8 8 dia F Roof Flashing PRF 7 1 12 7 12 pitch PRF 12 7 12 12 12 pt PRF 16 12 12 16 12 pt Figure 10 Straight vertical venting The elbow shown is a PEL 90F F which is connected directly to t...

Page 8: ...E Mantel clearances are for fire hazard prevention to combus tible materials New technology to meet consumer and government demands for the wise use of energy has prompted us to manufacture many models of fireplaces which are hot fuel and energy efficient Please be aware temperatures over the mantel will rise above nor mal room temperature and walls above fireplace may be hot to touch We recommend...

Page 9: ...ans for circulating heat into the living space Installations in Canada must be in accordance with CSA C22 1 Canadian Electrical Code Part 1 and or Local Codes Installations in the USA must be in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 1987 G L1 WH L2 BLK Quick Connect plug to motor Fan Switch Fan Switch Fan Motors 3 M38DV PFC I Fi...

Page 10: ...hat a good seal is maintained Operation Lighting Instructions See Pages 11 12 Figure 17 Removing inner doors 9 x machine screws Burner Adjustment The M38DV PFC is equipped with an adjustable burner allowing you to raise or lower the flames To adjust the flames locate the black knob marked Hi Lo in the centre of the gas control valve See Figure 26 The front burners are not adjustable To raise the f...

Page 11: ...ons If you cannot reach your gas supplier call the Fire To Turn Off Gas To Appliance Operation Model M38DV PFC 3 Push in gas control knob slightly and turn clock wise to Off Do not force 4 Replace lower trim 1 Turn off remote switch 2 Remove lower trim 1 STOP Read the safety information above on this label 2 Remove lower trims 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minu...

Page 12: ...area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor What To Do If You Smell Gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Remove lower trim Gas Inl...

Page 13: ...rotective coatings on new metal Glass must be cleaned periodically to remove any film a normal bi product of combustion which may be visible Film can easily be removed by removing the door as shown on page 10 Handle the door carefully and clean it with glass cleaners One of the most effective products is Kel Kem Silicone seals on inner door during initial firing will off gas leaving a visual depos...

Page 14: ... fo rservice INSET HSI Terminals C H EC K Linevo ltag ep o w er Lo wvo ltag e transfo rm er Lim itC o ntro ller Therm o stat W iring A irp ro vingsw itcho n co m b ustio nairb lo w ersystem Ventd am p er ifused iso p en andendsw itchm ad e Troubleshooting If your fireplace still does not operate correctly consult your dealer or the manufacturer All service and repairs should be performed by a qual...

Page 15: ...se of any components not manufactured or supplied by The Companies 2 The Montigo Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expres...

Page 16: ...4 5 6 Model M38DV PFC I Model M38DV PFC 5 16 Alum Tubing PSE 5 16 Alum Tubing 2 7 1 Fan Motor MBL 1 2 Power Cord PPCH 4 3 Stucco Frame MSR 4 Stucco Frame MOSR 5 Brick Frame BSR 6 Termination PTKO Series 7 Heat Guard PTKOG 8 Horizontal Trim Kits 9 Peninsula 5 Piece Fibre Logset 8 9 ...

Page 17: ...m in the United States 6 feet 1 8 m minimum in Canada L clearance to nonmechanical air supply inlet to building or the combus tion air inlet to any other appliance 16 inches 41 cm minimum for appliances 100 000 BTU H 30kW M clearance to mechanical air supply inlet 6 feet 1 8 m minimum N clearance above paved sidewalk or a paved driveway located on public property 7 feet 2 1 m minimum P clearance u...

Page 18: ...Canadian Heating Products Inc Surrey BC V3W 2V6 Montigo Del Ray Corp Ferndale WA 98248 XG0202 Rev 07 99 ...