Page 12
ME38-DV-2 Homefire
Part No. XG0110
Removing and Installing
the Insert
You may remove the insert to protect it from theft and damage during
construction.
1. Remove the two machine screws (1 left & 1 right) at the top of the
insert that attach the insert to the shell.
See Inset 1.
2. Remove the fresh air flex from the collars on the shell.
See Figure
22.
Important: Be careful not to damage the fresh air flex
during removal or storage.
3. Remove the 4 machine screws that hold the venting plate to the
insert.
4. Remove the insert by tipping the top of the insert outward and lifting
the tabs past the slots in the bottom of the shell.
See Inset 2.
Store the screws and clamps in a safe place to ensure that they are not
lost.
To re-install the insert simply reverse the steps above.
Figure 22.
ME38-DV-2 insert.
INSET 1
Tab
INSET 2
Mounting
Bracket
Fresh Air
Flex (4"
dia.)
High temp.
silicone seal
Venting Plate
Front
Slot
Installation
Figure 21a.
Wiring for optional air circulating fan kit.
G
L1-WH
L2-BLK
Quick Connect
plug to motor
Wiring for the
optional
Fan Kit
All 38 Series Modular fireplaces may be equipped with optional fan or
blower kits for circulating heat into the living space.
Installations in Canada which employ the fans must be electrically
grounded in accordance with CSA C22.1 Canadian Electrical Code
Part 1 and/or Local Codes.
Installations in the USA which employ the fans must be grounded in
accordance with local codes or, in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70-1987.
For more information see the Fan Kit Installation Guide included
with the fan kit.
NOTE:
If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.
Figure 21b.
Wiring schematic for optional fan kit.
115/1/60 Supply
G