Please review the Installation Checklist on Page 4 for general information 

on preparing for a successful installation of your fireplace.
The H-Series VO-ST fireplace may be installed in any location that 

maintains proper clearances to air conditioning ducts, electrical wiring 

and plumbing.  Safety, as well as efficiency of operation, should be 

considered when selecting the fireplace location.  Try to select a location 

that does not interfere with room traffic, has adequate ventilation and 

offers an accessible path for Direct Vent installation.

Figure 1.

  Fireplace dimensions, (ALL Models, shown in Table on Page 3). 

The fireplace dimensions are shown below:

Top View

 

h

Front View

  25¾"

Opening

 

h

6¾"

5¼"

 

Figure 2.

  Fireplace dimensions with optional Stainless Steel insulation jacket

Top View

Side View

36½"

Height

24"

24”

  

th

Front View

Opening

 

h

6 "

Installation

Section 1: 

Installation Overview and Product Dimensions

Summary of Contents for H38SVO-ST Series

Page 1: ...y hazard Rotating parts Low temperature Strong magnetic field Optical radiation Non ionizing radiation Radiation Hazardous to the Environment Danger of harming your hands Irritant Cutting Watch your step Slippery floor High temperatures Glass hazard Danger of suffocation High voltage Toxic Flammable materials Corrosive Fork lift trucks Danger overhead crane Explosion risk Oxidising Danger of death...

Page 2: ...talling the H34VO Log Set 11 Installing the H38VO Log Set 12 Installing the H42VO Log Set 13 Installing the HL38VO Firestones 14 Section 7 Operation 15 16 Start up Sequence with Continuous Pilot 15 Start up Sequence with Honeywell Electronic Ignition 16 Maintenance 17 18 General 17 Cleaning 17 Hi Lo Burner Adjustment 17 Pilot Burner Adjustment 17 Replacement Parts 18 Appendix A Termination Locatio...

Page 3: ... to ensure your safety This manual covers installation operation and maintenance Lighting operation and care of this fireplace can be easily performed by the homeowner All installation and service work should be performed by a qualified or licensed installer plumber or gas fitter as certified by the state province region or governing body where the fireplace is being installed Thisinstallation ope...

Page 4: ...t prior to starting the installation It is the responsibility of the installer to ensure this fireplace is installed in compliance with the manufacturers instructions and all applicable codes BEFORE YOU START Installation Installation and repairs should be done by an authorized gas fireplace service technician The appliance should be inspected before use and at least annually by a professional Mor...

Page 5: ... operation should be consideredwhenselectingthefireplacelocation Trytoselectalocation that does not interfere with room traffic has adequate ventilation and offers an accessible path for Direct Vent installation Figure 1 Fireplace dimensions ALL Models shown in Table on Page 3 The fireplace dimensions are shown below Top View h Front View 25 Opening h 6 5 Figure 2 Fireplace dimensions with optiona...

Page 6: ...traffic has adequate ventilation and offers an accessible pathway for ventilated gasses Backframe Min 38 both sides Typical 41 Surrounding construction bottom sides and top must e non combustible materials metal studs concrete board nd concrete brick or stone 40 41 23 7 8 38 36 Combustible materials Backframe Min 38 both sides Typical metal studs concrete board and concrete brick or stone des Fram...

Page 7: ...e non combustible materials metal studs c oncrete board and concrete b rick or stone 24 Min WARNING When covering the upper metal portion of the fireplace with a non combustible material Please Note The decorative facing materials may be subject to temperatures in excess of 350 F This should be considered when selecting facing materials Figure 6 Non combustible mantles and facings Backframe Min 38...

Page 8: ...es its own power on a millivolt circuit Use only low voltage wire and DO NOT connect any external power to it Refer to Figure 4 for wiring requirements Note The switch location must not exceed 30 from the fireplace Figure 7 Wiring for the H L 38VO ST N L E Honeywell gas control and pilot Figure 8 Standing Pilot Diagram H L 38VO ST Honeywell Q3450 Pilot Assembly Pilot Electrical Harness Connector H...

Page 9: ...verning body in which the fireplace is being installed Section 4 3 GAS CONNECTION See Figure 5 below for location of gas line access Flexible gas connectors must not exceed 3 feet in length unless allowable within local regulations Connect incoming gas line to the 1 2 or 3 8 gas inlet port Purge all air out of gas line Checkapplianceconnection valveandvalvetrainundernormal operating pressure with ...

Page 10: ...during maintenance or cleaning Install in reverse order Remove the Horizontal Access Panel To install the door hook the top edge of the door frame into place Lower thedoorintopositionandfollowthepreviousstepsshowninreverseorder Installing the Door 2 Step 5 Ensure the tool is firmly in the lower end of the slot as shown Then pull toward you Caution hold the tool securely 3 Step 6 Pull hard if neces...

Page 11: ... D are then mounted on top of logs A as shown in Figure 11e Warning If logs are not placed properly excessive sooting will result Figure 11d Log Installation Place Logs C on top of Logs A Indentations on top of Logs A Figure 11c Place Logs B as shown in front of Right hand A and behind Left hand B Log A Log B Log C Log A Log B Log C Figure 11e Completed log Installation Log D Log D Figure 11a Empt...

Page 12: ...removed place the glass beads across the pan surrounding the burners as shown in Figure 12 NOTE DO NOT Cover burners with beads or the optional rocks Figure 12 Installation of glass beads Note Ensure the beads do not cover the burners or pilot L42DF ST WARNING Do not attempt to clean glass when hot Do not clean glass with abrasive materials as any glass etching may cause premature glass failure Do...

Page 13: ...tinuous Pilot with American Flame Electronic Ignition For Your Safety READ BEFORE LIGHTING Lighting Instructions 1 STOP Read the safety information above on this label 2 Lift out the lower Horizontal access panel 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas including near the floor If you then smell gas STOP Follow B in the safety in...

Page 14: ...ediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Flip down the lower trim 3 Turn the switch on the gas control to Off 4 Flip up the trim 1 STOP Read the safety information above on this label 2 Flip down the lower trims 3 Turn switch on the gas control to OFF 4 Wait 5 minutes to clear out any gas If you smell gas STOP Follow...

Page 15: ...he appliance and to replace any part of the control system and any gas control which has been under water Cleaning When the fireplace is first activated there may be some smoking and a visible film may be left on the glass This is a normal condition and is the result of burning of protective coatings on new metal Glass must be cleaned periodically to remove any film which is a normal by product of...

Page 16: ... 34 Pilot Burner If your fireplace still does not operate correctly consult your dealer or the manufacturer All service and repairs should be performed by a qualified agency All spare parts optional fans and optional trim finishes are available from your local dealer or the manufacturer Troubleshooting Troubleshooting The following is a troubleshooting chart of possible problems PROBLEM CORRECTIVE...

Page 17: ...ppliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive...

Page 18: ... line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the...

Page 19: ...H 38VO ST Outdoor Gas Fireplace Page 19 XG0817 060611 Notes ...

Page 20: ...Ferndale Washington TF 1 800 789 6236 FX 1 866 3000 0927 XG0817 030412 Langley British Columbia TF 1 800 378 3115 FX 1 604 607 6462 H38VO ST Ventless Outdoor See Through Residential Gas Fireplace ...

Reviews: