EC Plus-4 Series B-Vent
®
Part No. XG0303C
Figure 2.
Framing dimensions.
Installing The Fireplace Shell
The.fireplace.may.be.installed.in.any.location.that.maintains.clear-
ances.to.air.conditioning.ducts,.electrical.wiring.and.plumbing..Safety,.
as.well.as.efficiency.of.operation,.must.be.considered.when.selecting.
the.fireplace.location..Try.to.select.a.location.that.does.not.interfere.
with.room.traffic,.has.adequate.ventilation,.and.offers.an.accessible.
pathway.for.the.optional.B-Vent.&.Combustion.Air.Kit.installation.
The.fireplace.dimensions.are.shown.below:
Installation
Figure 1.
Fireplace dimensions.
Clearances
The.
EP-28 Series
clearances.to.combustible.materials.are:
Top*
12"
Back
0"
Sides
1"
Floor
0"
Mantle**
6"
Recess Depth***
15"
*. Clearance.from.the.top.of.the.fireplace.to.
a.combustible.ceiling,.within.the.fireplace.
enclosure.
**. Refer.to.page.5.
See.Figure.2.
Framing
For.protection.against.freezing.temperatures,.it.is.recommended.that.
outer.walls.of.the.chase.be.insulated.with.a.vapour.barrier..This.will.
reduce.the.possibility.of.a.cold-air.convection.current.on.the.fireplace.
37 1/2
15 1/2*
36
*. When.sheetrock.is.not.used.behind.the.fireplace,.framing.
depth..may.be.reduced.to.14.3/4"
37 1/2
31 1/4
19
9 1/2
4' B-Vent
14 3/4
C
Top View
Front View
Side View
4".B-Vent
WARNING
:
When.this.appliance.is.installed.directly.on.carpeting,.tile.or.any.
combustible.material.other.than.wood.flooring,.it.must.be.installed.
on.a.metal.or.wood.panel.extending.the.full.width.and.depth.of.
the.appliance.
Figure 3.
Corner Installation - framing dimensions.
1
14 3/4
9 1/2
9
38
37
53
1/2