background image

P/N XG0515

Page 17

Tuscany

 Gas Fireplace Insert

Installation

Appendix A Warranty

The Warranty

The Companies warrants the DelRay Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the DelRay, there is a 

ten-year warranty on the firebox and its components, a five-year warranty on the main burner, and a one-year warranty on the gas control valve, pilot burner and 

fibre logs. Glass, plated/painted finishes, and refractory lining are exempt.

Remedy And Exclusions

The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by The Companies.
This Warranty only covers DelRay Gas Appliances installed in the United States or Canada.
If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see The Companies right of investigation 

outlined below). The Companies will, at its option, replace or repair defective components of the Gas Appliance manufactured by The Companies at no charge, 

and will also pay for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not commercially practical, The Companies 

will, at its option, refund the purchase price of the DelRay Gas Appliance. 
This Warranty covers only parts and labour as provided above. In no case shall The Companies be responsible for materials, components, or construction which 

are not manufactured or supplied by The Companies, or for the labour necessary to install, repair or remove such materials, components or construction. All 

replacement or repair components will be shipped F.O.B. the nearest The Companies factory. 

Qualifications To The Warranty

The Gas Appliance Warranty outlined above is further subject to the following qualifications:
(1)  The Gas Appliance must be installed in accordance with The Companies installation instructions and local building codes. The Warranty on this DelRay Gas 

Appliance covers only the component parts manufactured by The Companies. The use of components manufactured by others with this DelRay Gas Appliance 

could create serious safety hazards, may result in the denial of certification by recognized national safety agencies, and could be in violation of local building 

codes. This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies 

(2)  The DelRay Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such 

as wood, coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.

Limitations On Liability

It is expressly agreed and understood that The Companies sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty, 

expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.
In no event shall The Companies be responsible for any incidental or consequential damages caused by defects in its products, whether such damage occurs 

or is discovered before or after replacement or repair, and whether or not such damage is caused by The Companies negligence. Some states do not allow the 

exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty 

with respect to this DelRay Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty 

lasts, so the above may not apply to you.

Investigation Of Claims Against Warranty

The Companies reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.
The Companies Are Not Responsible For Work Done Without Written Consent
The Companies shall in no event be responsible for any warranty work done without first obtaining The Companies written consent.
Dealers Have No Authority To Alter This Warranty
The Companies employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those stated above.

How To Register A Claim Against Warranty

In order for any claim under this Warranty to be valid, The Companies must be notified of the claimed defect in writing or by telephone, as soon as reasonably 

possible after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.

Other Rights

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

note:

 

The Companies

 as stated above refer to - Canadian Heating Products Inc. and/or Montigo Del Ray Corp.

Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without notice, in design, materi-

als, specifications, prices and also to discontinue colors, styles and products.

Summary of Contents for DelRay Tuscany 34DVI

Page 1: ...lectricity Danger for cutter Entrapment hazard Battery hazard Rotating parts Low temperature Strong magnetic field Optical radiation Non ionizing radiation Radiation Hazardous to the Environment Danger of harming your hands Warning Iftheinformationintheseinstructions is not followed exactly a fire or explosionmayresultcausingproperty damage personal injury or death Irritant Cutting Watch your step...

Page 2: ...e retain this owner s manual for future reference Safety Alert Key 3 Introduction 3 Models 3 Warranty Information 3 Overview 4 Before You Begin 4 Clearances 4 Inspecting Cleaning the Chimney 4 Section 1 Installation 5 Installing the Gas Line 5 Installing the Chimney Liner 5 6 Section 2 N A Section 3 N A Section 4 N A Section 5 N A Section 6 N A Section 7 Removing and Installing the Door 7 Installi...

Page 3: ...r of death Biohazard Laser Radiation Danger of entrapment Hot surface General Warning Blank Gas bottles Watch for falling objects Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts Low temperature Strong magnetic field Optical radiation Non ionizing radiation Radiation Hazardous to the Environment Danger of harming your hands Safety Alert Key Irritant Cutting Watch your ...

Page 4: ...e outside of the chimney and masonry for damage including cracked loose or damaged bricks andmortar orothermaterialsthatcouldinhibitthecorrect installationoftheflexiblechimneyliner Ensurethatanydamage or deterioration has been properly repaired Removeanyglazedcreosotethathasbuilt upinsidethechimney The existing passageway must be cleared of any obstructions that would prevent the flex liner instal...

Page 5: ... control valve is located underneath the firebox in the control compartment The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure...

Page 6: ...e pipe with the screws provided Seal between the flashing and chimney cap with high temperature silicone See figure 6 STEP 6 Run a wide bead of silicone along the top of the clay liner and press the flashing and chimney cap down on top of the chimney STEP 7 Before placing the Tuscany in its location lay a piece of cardboard on the hearth to protect it Place the Tuscany just in front of the firepla...

Page 7: ...fireplace opening and ensure that both the air intake and exhaust vents are properly installed As per previous section 3 Ensure that the gas line is properly connected to the flexible gas connector and tested for any leaks 4 Position the backing plate along the top of the insert and attach it using the three screws provided See figure 10a below 5 Loosen the four screws on the inside edge of the fa...

Page 8: ...igure 12 Slide the insert into place Wiring Instructions for the Fan Switch Circuit 6 Connectthewirewiththeplastic Molex connectorontheleftsideof the control compartment to the wire which leads to the Fan Sensor Switch Run the fan s power cord out through the small notch on the bottom left side of the faceplate Figure 11b Wiring Schematic for the fan circuit Wiring Instructions for the On Off Circ...

Page 9: ... Start the fireplace If the flame appears satisfactory replace the glass door If the flame does not appear satisfactory double check the air inlet and exhaust outlet pipe to ensure that they are unobstructed 2 The back log is factory installed along with the ceramic brick liner as shown below in figure 12b 3 Place the Front log onto the front log rest as shown in figure 12c The log has lip on the ...

Page 10: ...34HDVI The Tuscany 34HDVI is supplied with a six ceramic fibre log logset Unpack the logs and handle them very carefully Step 1 RemovetheglassdoorasdescribedinthepreviousInstructions Air Inlets Pilot Assembly Fireplace Base Rear Bottom Log Notch in Log Log A Air Inlets Fireplace Base Log D Figure 27c Top Left Log Log D Air Inlets Fireplace Base Log E Step 5 Place Front Left log Log D as shown in f...

Page 11: ...r cutter Entrapment hazard Battery hazard Rotating parts Low temperature Strong magnetic field Optical radiation Non ionizing radiation Radiation Hazardous to the Environment Danger of harming your hands Caution DO NOT COVER THE BURNERS WITH FIRESTONES OR FAUX RIVER ROCKS 1 Remove the glass door as described in the previous Instructions Back of Fireplace Air Inlets Figure 29a Firebox prior to faux...

Page 12: ...and will settle on the floor What To Do If You Smell Gas Q Q Do not try to light any appliance Q Q Do not touch any electrical switch do not use any phone in your building Q Q Immediately call your gas supplier from a neighbour s To Turn Off Gas To Appliance 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Replace the lower Horizontal access panel 1 Turn off remote swit...

Page 13: ...round the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor What To Do If You Smell Gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s To Turn Off Gas To Appliance 3 Push in gas control knob slightly and turn clo...

Page 14: ...trol knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas including near the floor If you then smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 5 Locate pilot burner and follow steps below 6 Turn knob on gas control counterclockwise to PI LOT 7 Push in gas control knob completely and hold Light with ...

Page 15: ... fireplace is first activated there may be some smoking and a visible film may be left on the glass This is a normal condition and is the result of burning of protective coatings on new metal Glass must be cleaned periodically to remove any film which is a normal by product of combustion which may be visible Film can easily be removed by removing the door as shown on Page 20 Handle the door carefu...

Page 16: ...DVI 34HDVI 34RDVI NG Gas Valve RGC1021 RGC1015 RGC1006 RGC1006 LG Gas Valve RGC1022 RGC1016 RGC1005 RGC1005 NG Pilot RPA020 RPA020 RPA020 RPA020 LP Pilot RPA021 RPA021 RPA021 RPA021 Front Burner NG RBT1099 Rear Burner LPG Front Orifice NG Rear Orifice LPG Logs Spare Parts List ...

Page 17: ...ance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive rem...

Page 18: ...Page 18 Tuscany Gas Fireplace Insert P N XG0515 Installation ...

Page 19: ...ght of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve ...

Page 20: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0515 120507 ...