background image

The Warranty

The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a ten-

year warranty on the firebox and its components, a five-year warranty on the main burner, and a one-year warranty on the pilot burner, gas control valve and fibre logs. 

Glass, plated/painted finishes, and refractory lining are exempt.

Remedy And Exclusions

The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by The Companies.
This Warranty only covers Montigo Gas Appliances installed in the United States or Canada.
If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see The Companies right of investigation 

outlined below). The Companies will, at its option, replace or repair defective components of the Gas Appliance manufactured by The Companies at no charge, and 

will also pay for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not commercially practical, The Companies will, at its 

option, refund the purchase price of the Montigo Gas Appliance. 
This Warranty covers only parts and labour as provided above. In no case shall The Companies be responsible for materials, components, or construction which are 

not manufactured or supplied by The Companies, or for the labour necessary to install, repair or remove such materials, components or construction. All replacement 

or repair components will be shipped F.O.B. the nearest The Companies factory. 

Qualifications To The Warranty

The Gas Appliance Warranty outlined above is further subject to the following qualifications:
(1)  The Gas Appliance must be installed in accordance with The Companies installation instructions and local building codes. The Warranty on this Montigo Gas 

Appliance covers only the component parts manufactured by The Companies. The use of components manufactured by others with this Montigo Gas Appliance 

could create serious safety hazards, may result in the denial of certification by recognized national safety agencies, and could be in violation of local building codes. 

This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies 

(2)  The Montigo Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such as 

wood, coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.

Limitations On Liability

It is expressly agreed and understood that The Companies sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty, expressed 

or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.
In no event shall The Companies be responsible for any incidental or consequential damages caused by defects in its products, whether such damage occurs or is 

discovered before or after replacement or repair, and whether or not such damage is caused by The Companies negligence. Some states do not allow the exclusion 

or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty with respect to 

this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above 

may not apply to you.

Investigation Of Claims Against Warranty

The Companies reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.
The Companies Are Not Responsible For Work Done Without Written Consent
The Companies shall in no event be responsible for any warranty work done without first obtaining The Companies written consent.
Dealers Have No Authority To Alter This Warranty
The Companies employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those stated above.

How To Register A Claim Against Warranty

In order for any claim under this Warranty to be valid, The Companies must be notified of the claimed defect in writing or by telephone, as soon as reasonably possible 

after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.

Other Rights

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

NOTE:

 

The Companies

 as stated above refer to - Canadian Heating Products Inc. and/or Montigo Del Ray Corp.

Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without notice, in design, materials, 

specifications, prices and also to discontinue colors, styles and products.

Appendix A - Warranty

Page 16

XG0702

C-View Custom Fireplace

Appendix

Summary of Contents for CFPO-10

Page 1: ...ks Danger overhead crane Explosion risk Oxidising Danger of death Biohazard Laser Radiation Danger of entrapment Hot surface General Warning Blank Gas bottles Watch for falling objects Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts Low temperature Strong magnetic field Optical radiation Non ionizing radiation Radiation Hazardous to the Environment Danger of harming y...

Page 2: ... 9 Installing the Gas Line 11 Section 10 Installing the Burner Accessories 12 Installing the Firestones 12 Operation 13 Section 11 Start Up 13 Maintenance 14 Section 12 General Maintenance and Cleaning 14 Annual Inspection Checklist 14 Section 13 Troubleshooting 15 Appendix 16 Appendix A Warranty 16 Appendix B State of Massachusetts 17 Page 2 Table of Contents Custom C View Fireplace XG0702 You mu...

Page 3: ...maintenance Lighting operation and care of this fireplace can be easily per formed by the end user All installation and service work should be performed by a qualified or licensed installer plumber or gas fitter as certified by the state province region or governing body where the fireplace is being installed Thisinstallation operationandmaintenancemanualisapplicable tothemodelsdescribedbelow Refe...

Page 4: ...ot covered however if you wish to place it in a covered area there are strict guidelines that must be adhered to in Section 3 Place the unit in a location that is least affected by wind Firepits have an open flame that can cause injury Consider the safety of children and other indi viduals during placement Montigo requires that all framing in direct contact with the unit be of non combustible cons...

Page 5: ...ss than 2 sides will be fully open there must be one side open such that there is 10 square feet of fresh air per 20 000 BTU of your unit Also you must install a Montigo interlocking carbon monoxide detector in the furthest location from the opening Part No EBOX A310 Fig 2 Covered Installation Option 1 Fig 3 Covered Installation Option 2 Fig 4 Covered Installation Option 3 Clearances to Surroundin...

Page 6: ...underneath by non combus tible framing spaced no more than two feet apart Do not support the firepit by its surrounding lip Additionally ensure that all surrounding materials are non combustible or follow the clearances to combustibles given in this manual The inner dimensions of your surround framing are recom mended to be Dimension G Fig 6 plus 1 inch by Dimension C Fig 6 plus 1 inch This will g...

Page 7: ... CFPO 9 26 65 CFPO 10 30 00 Section 6 Combustion Air Supply Fresh Air Supply Grille Fig 9 Fresh Air Supply Grille Non Combustible Surround Fig 8 Framing Diagram Gas In Fresh Intake Air Min 3 From Bottom of Cross Supports to Floor 6 Clearance Shown Here 1 Min Clearance to Non Combusti ble Materials All Around 4 x 18 Screened Opening Shown Here Do Not Install Cross Supports Directly In Line with Int...

Page 8: ... Single Phase 110 Volt AC 5 Amp NEMA 5 15P Power Output from Transformer 24VAC 40VA Max Gas Valve Firepit On Off Switch Plug Black Black Red Red Black White Green 110V 24V 6 375 7 875 8 5 8 5 4 625 Replacement Parts available from your local Montigo dealer Section 7 Electrical Control Panel This control panel will be used for units with 1 gas valve including CFPO 2 CFPO 3 CFPO 4 CFPO 5 CFPO 6 CFPO...

Page 9: ...upply Single Phase 110 Volt AC 5 Amp NEMA 5 15P Power Output from Transformers 24VAC 40VA Max Gas Valve 1 Firepit On Off Switch Plug 110V 24V 24V 110V Gas Valve 2 Black Black Red Red Black White Green Brown Red 6 375 7 875 8 5 8 5 4 625 Replacement Parts available from your local Montigo dealer This control panel will be used for units with 2 gas valve including CFPO 9 CFPO 10 and larger custom si...

Page 10: ...e glow plug will light the pilot and establish a pilot flame The pilot flame is recognized by the flame sensor rod and sends a signal to the valve to open the main burner Any distortion of the flame pattern will give the valve a faulty signal and turn the main burner off If the air movement of the system is too erratic the air may move the pilot flame from the sensor rod and turn the valve off Aft...

Page 11: ...the floor because some gas is heavier than air and will settle on the floor What To Do If You Smell Gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life The gas connection is located on the underside...

Page 12: ... across the pan and the burners as described in Figure 14 to 14d Note Only cover the burner with one layer of designer fire stones Figure 14 Installation of the firestones Ensure ONLY one layer of firestones cover the surface Figure 14a Spreading the firestones evenly and make sure there are no firestones covering the pilot Figure 14b Completed firestone installation Figure 14c Completed firestone...

Page 13: ... mounted on the side of the control panel 3 The control panel will supply power to the Honeywell smart valve The glow plug will light the pilot and establish a pilot flame The pilot flame is recognized by the flame sensor rod and sends a signal to the valve to open the main burner Any distortion of the flame pattern will give the valve a faulty signal and turn the main burner off If the air moveme...

Page 14: ...shed when cleaning appliance General Have the firepit installation inspected yearly including a visual check of the vent system the burner and the pilot flame For your convenience a 1 8 manifold pressure tap is supplied on the gas valve for a test gauge connec tion For Natural Gas this appliance requires a minimum inlet pressure of 5 5 wc and a manifold pressure of 3 5 wc For Propane this applianc...

Page 15: ... Support Yes 1 minute system purge Smart valve relay on Hot surface igniter glows No Yes Pressure switch trip Failed purge timer Yes Pilot flame lights No Control cable not connected Pilot assembly failure Smart valve failure No Air in gas line Gas not turned on Yes Igniter off Smart valve opens Main burner lights No Pilot not touching flame rod Poor ground connection Turn wall switch off Fireplac...

Page 16: ...nly Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under this Warranty under any other warranty expressed or implied or in contra...

Page 17: ...horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector observes carbon monoxide detectors...

Page 18: ...Ferndale Washington TF 1 800 789 6236 FX 1 866 3000 0927 XG702 092711 Langley British Columbia TF 1 800 378 3115 FX 1 604 607 6462 CFPO Custom Outdoor Firepit ...

Reviews: