 INTRODUCTION

Congratulations, you are now the proud owner of the very attrac-
tive Montigo 36SR fireplace.  Please read all of the installation
insructions carefully to assure that your new fireplace will give you
all the comfort and enjoyment you expect.  The Montigo 36SR is a
vented appliance and must be installed to a vented system.    Consult
your local Gas Inspection Branches for specifics.

The Montigo 36SR is rated at 40,000 BTU's.

The Montigo warranty will be voided by, and Montigo disclaims
any responsibility for, the following actions:

-Modification of the fireplace and/or components including

B-vent assembly or glass doors.

-Use of any component part not manufactured or approved by

Montigo in combination with a Montigo fireplace system.

-Installation other than as instructed in this manual.

Consult your local Gas Inspection Branch about the particular
requirements concerning installation of factory-built gas fireplaces.
All work should be done by a qualified contractor, and installation
must conform with the current CAN/CGA B-149 Gas Installation
Code and local regulations.

The fireplace is not  intended to be used as a
substitute for a  furnace to heat an entire home.
Use for supplemental heating only.

  SELECTING YOUR FIREPLACE LOCATION

The fireplace may be installed in any location that is free of air
condition ducts, electrical wiring and plumbing.  Safety, as well as
efficiency of operation, must be considered when installing
a fireplace, select a location that does not interfere with room traffic,
has adequate ventilation, and offers an accessible pathway for B-
Vent installation.

The fireplace dimensions are shown below:

NOTE: these are not framing dimensions (see Figure 2 for
framing dimensions.

FIGURE 1.  FIREPLACE DIMENSIONS

36

20 1/4*

36

4

21 3/4

68

48

39

4 1/2

Sq.

19 1/2

32 1/8

12 1/2

26 1/4

11

 

 

CAUTIONS

  *Due to its high operating  temperatures, the appliance should  be

located  out  of  traffic  &  away   from  furniture  and draperies.

  *Children and adults should be alerted to the hazards of the high

surface temperature, which could cause burns or clothing ignition.

  *Young children should be carefully  supervised when they are in

the same room as the appliance.

  *Clothing or other  flammable  materials should not be placed on

or  near  the  appliance.

  INSTALLING THE FIREPLACE

The Montigo 36SR clearances  to  combustible materials  are 0"
back, 1" sides, 0" floor and 4" top. The Montigo 36SR must  not be
installed any closer than 8 inches to any  unprotected combustible
wall perpendicular to the fireplace opening.

For the protection against freezing temperatures, it is
recommended that the outer walls of the chase be insulated with a
vapour barrier.  This will reduce the possibility of a cold-air
convection current on the fireplace.

The B-vent system requires clearance of 1" minimum air space.

The framing dimensions are shown below:

FIGURE 2.  FRAMING DIMENSIONS

  INSTALLING THE REMOTE SWITCH

The  Montigo 36SR is equipped with a remote-operated valve,
located behind the removable grille, at the bottom of the fireplace.
(Refer to Figure 5 on the last  page.)  The valve is pre-wired and
completely self-contained and self-powered:  DO NOT  connect any
external power to it.

2

7

20 1/4*

39 1/2

39 1/2

* Allows 3/4" spacing for

drywall. Framing depth may
be reduced to 19 1/2" if no
drywall is used.

Summary of Contents for 36SR

Page 1: ...F YOU SMELL GAS 1 OPEN WINDOWS DO NOT STORE OR USE ANY FLAMMABLE 2 DON T TOUCH ELECTRICAL SWITCHES VAPOURS OR LIQUIDS NEAR THIS OR ANY 3 EXTINGUISH ANY OPEN FLAME OTHER GAS BURNING APPLIANCE 4 IMMEDIATELY CALL YOUR GAS SUPPLIER READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING MODEL MONTIGO 36SR CANADIAN HEATING PRODUCTS INC 12091 88th Avenue Surrey B C Canada V3W 3J5 Ph 604 597 3115 Fax 604 597 3096 ...

Page 2: ...and offers an accessible pathway for B Vent installation The fireplace dimensions are shown below NOTE these are not framing dimensions see Figure 2 for framing dimensions FIGURE 1 FIREPLACE DIMENSIONS 36 20 1 4 36 4 21 3 4 68 48 39 4 1 2 Sq 19 1 2 32 1 8 12 1 2 26 1 4 11 CAUTIONS Due to its high operating temperatures the appliance should be located out of traffic away from furniture and draperie...

Page 3: ... B Vent to the L shaped brackets on each side of the opening with 1 4 sheet metal screws Do not penetrate the inner sleeve of the B Vent when tightening the screws Refer to the current CAN CGA B 149 Gas Installation Code for specific vent sizing installation instructions The following table is provided as a guide for types of B Vent to use with common installations These values have been formulate...

Page 4: ...at allowing a longer time to elapse before releasing dial d To light the main burner turn dial to ON then turn on remote switch e Turn off flame with remote switch For complete shut down slightly depress gas control valve dial and turn to OFF position To Power Pile To Switch Pilot Adjustment Cap 1 8 N P T Pressure Tap MAINTENANCE Have the fireplace installation inspected yearly including a visual ...

Page 5: ...ure 8 FIGURE 7 BIFOLD DOOR MOUNTING To install the door kit in the Montigo 36SR a To install left door place bottom pivot into bottom door hole Push top spring clip upwards using a screwdriver and snap top pivot into top spring clip hole Repeat above procedure to install right door b Doors may be adjusted by simply loosening spring clip screw and adjusting door into square c Doors may be adjusted ...

Page 6: ...ted to normal use The decorative gas appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the decorative gas appliance will produce excessive temperatures and will result in a fire hazard LIMITATIONS ON LIABILITY It is expressly agreed and understood that Canadian Heating Products Inc s sole obligation and Purc...

Reviews: