INTRODUCTION
The Montigo 36DV-RV is rated at 18,000 BTUs. (5.20 Kilowatts)
for Natural & Propane gas.
The Montigo warranty will be voided by, and Montigo disclaims
any responsibility for, the following actions:
- Modification of the fireplace and/or components including
Direct-Vent assembly or glass doors.
- Use of any component part not manufactured or approved by
Montigo in combination with a Montigo fireplace system.
- Installation other than as instructed in this manual.
Consult your local Gas Inspection Branch about the particular
requirements concerning installation of factory-built gas fireplaces.
Installation & repairs should be done by a qualified contractor,
and installation must conform with the current CAN/CGA
B-149.1 and .2 Gas Installation Code and local regulations.
CAUTIONS
* Due to its high operating temperatures, the appliance should be
located out of traffic & away from furniture and draperies.
* Children and adults should be alerted to the hazards of the high
surface temperature, which could cause burns or clothing ignition.
* Young children should be carefully supervised when they are in
the same room as the appliance.
* Clothing or other flammable materials should not be placed on
or near the appliance.
SELECTING YOUR FIREPLACE LOCATION
The fireplace may be installed in any location that is free of air
condition ducts, electrical wiring and plumbing. Safety, as well as
efficiency of operation, must be considered when selecting the
fireplace location. Try to select a location that does not interfere
with room traffic, has adequate ventilation, and offers an accessible
pathway for Direct Vent & Combustion Air Kit installation.
The fireplace dimensions are shown below:
NOTE: SEE FIGURE 2 FOR FRAMING DIMENSIONS
FIGURE 1. FIREPLACE DIMENSIONS
19
16 1/4
10 1/4
37 1/2
3 3
39 1/2
INSTALLING THE FIREPLACE
The Montigo 36DV-RV clearances to combustible materials are 0"
back, 1" sides, 0" floor and 4" top. The Montigo 36DV-RV must not
be installed any closer than 8 inches to any unprotected
combustible wall perpendicular to the fireplace opening.
For protection against freezing temperatures, it is recommended that
the outer walls of the chase be insulated with a vapour barrier. This
will reduce the possibility of a cold-air convection current on the
fireplace.
THE FRAMING DIMENSIONS ARE SHOWN BELOW:
17
36
25 1/2
12
12
37 1/2
12
12
36
25 1/2
17
37 1/2
FIGURE 2. FRAMING DIMENSIONS
37 1/2
59
16 1/4
19
12
42