Press the button to get desired fan speed, Low to High.

Press the button to get desired fan speed, High to Low.  

Press the OFF button to turn fan off. 

Press this forward/reverse button to get desired airflow 

direction. Fan must be running to reverse. It will take about 25 

seconds for fan to slow down and change rotation direction. 

Note

: Fan will maintain last setting if turned off by a wall switch. 

 

The buttons on the remote control transmitter control the fan speed and light 

as follows. 

(Fig. 4) 

Down Speed

Turn Fan Off

LED Indicator

Fan/R

UP Speed

Remote Transmitter

Fig.4

Tips for end users

1. If your fan is operated automatically after installation and power on, it is because your fan is still memorize the previous 

setting at factory. Use universal mode or make learn function setting and your fan will be ready for use.  
2. If fan or light isn’t working, reset power (turn the power off for at least 5 seconds, then turn the power back, and wait for 5 

seconds at least) and redo the learn function setting. You must press the “SET” button within 1 minute of restoring power to the 

fan.
3. It is not available to separately operate the remote setting for more than one fan in the same room (in the area where remote 

signal can reach to) if they share the same power supply. Separate power supplies (like as using individual wall switches for each 

fan and turn power off for the fan while you are making learn function for other fan) is required if you want to separately control 

more than one fan in same room.
4. You may erase the code setting of the transmitters by turning the power off for at least 5 seconds, then turn power back and 

wait for at least 5 seconds then push and hold the “OFF” button of the transmitter which you are using for at least 10 seconds. 

You must press the ‘OFF” button within 60 seconds of restoring power to the fan.  

   

5. When fan is turned on or operated forward/reverse function, it shutters & goes back & forth until it turns. It is a normal 

performance of this fan and it will take for few seconds to run this operation.

The receiver provides the following protective functions

Lock protection- The DC motor has a build-in safety feature against 

blade or motor obstruction during operation. If something obstructs 

the fan blades or motor, the motor will keep trying to run for 3 

times and then stop operation after about 30 seconds of 

interruption. Please remove obstacles and reset. To reset it by turn 

the fan off by remote transmitter and then turn the fan on. 

Over load protection (current limit)- The device will limits the 

maximum current output from the receiver/drive when the fan load 

was increased abnormally. 

Summary of Contents for Maverick II 3MAVR52 Series

Page 1: ...PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 3MA...

Page 2: ...Do Not Remove Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist Attach the mou...

Page 3: ...the mounting bracket with the holes of the outlet box Reinstall the 2 outlet box screws securely For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and down...

Page 4: ...install them will result in serious injury Install ball end of downrod into mounting bracket opening Align engage slot on ball with tab on mounting bracket Warning Failure to align slot on ball with t...

Page 5: ...quipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splices after being made should be turned upward and pushed carefully up int...

Page 6: ...ntroller is ready to use Fig 3 Note If using universal mode your fan can be controlled with other remote transmitters with the same setting To control the fan with specific remote transmitter choose L...

Page 7: ...where remote signal can reach to if they share the same power supply Separate power supplies like as using individual wall switches for each fan and turn power off for the fan while you are making le...

Page 8: ...f this is a downrod mount fan make sure the ridge on mounting bracket engages the notch in the downrod ball 2 Make sure that canopy mounting bracket or mounting plate are tightened securely to 4 Check...

Page 9: ...Apr 2018...

Reviews: