background image

© 2013 Monte Carlo Fan Company

11/1/2013

7

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

CAUTION:  Make sure main power is turned off.

3.Make sure forward/reverse switch is firmly in up or down position.  Fan will not operate when

switch is in the middle.

4.Make sure that shipping stabilizer tabs have been removed from motor.

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each other

or against the interior wall of the switch housing.

CAUTION:  Make sure main power is turned off before entering switch housing.

4.If using an optional Ceiling Fan Light Kit, check to be sure the screws securing the glassware

are finger tight.  Check to be sure light bulb is tight in socket and not touching glass shade(s).

If vibration persists from glass, remove glass and install a 1/4" wide rubber band on glass neck

to act as an insulator. Replace glass and tighten screws against rubber band. 

5.Some fan motors are sensitive to signals from Solid State variable speed controls.  

DO NOT USE a Solid State variable speed control.

6.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear

after this period.

1.Make sure that the ridge of the canopy engages the notch in the downrod ball. 

2.Check that all blades are screwed firmly into blade holders.

3.Check that all blade holders are tightened securely to motor.

4.Make sure that canopy and mounting bracket are tightened securely to ceiling junction box

and junction box is mounted firmly to ceiling joist.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by se-

lecting a point on the ceiling above the tip of one of the blades. Measure this distance from

blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade is posi-

tioned for measurement. Repeat for each blade. If all blade levels are not equal, you can adjust

blade levels by the following procedure. To adjust a blade tip down, insert a washer (not sup-

plied) between the blade and blade holder at the screw closest to the motor. To adjust a blade

tip up, insert washer (not supplied) between the blade and blade holder at the two screws far-

thest from the motor.  Reverse the position of the washer if blades mount from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redis-

tribute the weight and possibly result in smoother operation.

1.Check blue wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulbs.

CAUTION:  Make sure main power is turned off before entering switch housing.

2. If fan sounds noisy:

1. If fan does not start:

3. If fan wobbles:

4. If light does not work:

T

ROUBLe

S

HOOTING

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring.

In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this

Trouble Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty in installation, please call

our Customer Service Center at the 

number printed on your parts list insert sheet. 

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service discon-

necting means to prevent power from being switched on accidentally.  When the service disconnecting

means cannot be locked, securely fasten a 

prominent warning device, such  as a tag, to the service panel.

Trouble

Suggested Remedy

Summary of Contents for 5MS52 Series

Page 1: ...ipt to this card and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 5MS52XX Series Fan Total fan weight UL Model No 5MS52 7 6kgs 16 8 lbs ...

Page 2: ...s Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade WARNING To Reduce The Risk Of Fire Electric Shock or Personal Injury Mount To Outlet Box Marked Acceptable for Fan Support of 15 9 kg 35 lbs or less And Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the...

Page 3: ...let box suitable for fan support and use only the screws provided with the out let box must support 35 lbs Before attaching fan to outlet box ensure the outlet box is se curely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Use only the screws provided with the outlet box 3 Canopy Canopy disk Yoke cover Hang assembled fan from the mounting b...

Page 4: ...nnect Ground leads from mounting bracket and downrod to Ground lead from house Refer to Safety Tips section of manual 10 Canopy disk House Fan Blue Black White Green Black White Ground Place blade holders onto blades aligning holes in blade holder with holes in blade Make sure that the side of the blade you select is facing downward Install 3 screws and fiber washers to back side of blade as shown...

Page 5: ...ts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded con ductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 26 Connect black and blue wire from fan to Black or Hot wire from house Connect White wire from Fan to White...

Page 6: ...of blade as shown Tighten screws securely Repeat this process 4 more times until all blades are assembled Install blades to motor using the 10 motor screws provided Tighten screws securely 28 29 Install switch cap to fan using the 3 screws provided Tighten securely Setting the reverse switch in the left hand side will result in down ward airflow and setting the switch in the right hand side will r...

Page 7: ...evels are unequal Check this level by se lecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is posi tioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washe...

Page 8: ...Jan 2012 New format Nov 2013 Update for CUL regulation ...

Reviews: