Monte Carlo Fan Company 5MQ60XX Series Owner'S Manual Download Page 5

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

3.Check to make sure the dip switches from the transmitter and receiver are set on the same

frequency.

CAUTION:  Make sure main power is turned off.

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each other

or against the interior wall of the switch housing.

CAUTION:  Make sure main power is turned off before entering switch housing.

4.Some fan motors are sensitive to signals from Solid State variable speed controls.

DO NOT USE a Solid State variable speed control.

5.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear

after this period.

1.Make sure that the ridge of the canopy engages the notch in the downrod ball. 

2.Check that all blades are screwed firmly into blade holders.

3.Check that all blade holders are tightened securely to motor.

4.Make sure that canopy and mounting bracket are tightened securely to ceiling junction box

and junction box is mounted firmly to ceiling joist.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by

selecting a point on the ceiling above the tip of one of the blades. Measure this distance from

blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade is posi-

tioned for measurement. Repeat for each blade. If all blade levels are not equal, you can adjust

blade levels by the following procedure. To adjust a blade tip down, insert a washer (not sup-

plied) between the blade and blade holder at the screw closest to the motor. To adjust a blade

tip up, insert washer (not supplied) between the blade and blade holder at the two screws far-

thest from the motor.  Reverse the position of the washer if blades mount from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redis-

tribute the weight and possibly result in smoother operation.

1.Check wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulbs.

CAUTION:  Make sure main power is turned off before entering switch housing.

2. If fan sounds noisy:

1. If fan does not start:

3. If fan wobbles:

4. If light does not work:

Trouble Shooting

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation,

or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults,

please check this Trouble Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty

in installation, please call our Customer Service Center at the number printed on your parts list insert sheet. 

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service dis-

connecting means to prevent power from being switched on accidentally.  When the service dis-

connecting means cannot be locked, securely fasten a prominent warning device, such  as a tag,

to the service panel.

Customer Service Center

740 S.W. Loop 820, Suite 110

Fort Worth, Texas 76115

1-800-519-4092

Summary of Contents for 5MQ60XX Series

Page 1: ...Owner s Manual Ceiling Fan Installation Instructions For 5MQ60XX Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight Quality Ceiling fans ...

Page 2: ...f fuel burning equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel a...

Page 3: ...king the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 17 Fan and light kit combinations over 70 lbs in both flush and downrod mode the safety cable must be installed into the house structure beams using the 3 lag screws washers and lock w...

Page 4: ...e canopy with the two holes in the hanger bracket Secure with two screws provided 21 Light Switch Fan Switch Wall Control Re install safety bar removed in step 3 by placing safety bar on screws sliding into place and tight ening the 2 screws 20 Loosen 3 screws with key slots and remove 1 screw without slot from motor plate and save screw 25 Install 3 screws and washers per blade and tighten secure...

Page 5: ... blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not sup plied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws far thest from the motor Reverse the position of the washer if blades mount from top o...

Reviews: