Cautions and Warnings

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70), including 

fire-rated construction.
Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
After making

 

the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side 

of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be turned upward and pushed 

carefully up into the outlet box.

WARNING:

 Before you begin installing, servicing or cleaning the fan unit, switch the power off at the service panel and lock the service panel to prevent 

the power from being switched back on accidentally. If the service panel cannot be locked to prevent the power from being switched on accidentally, 

securely fasten a warning sign to the service panel.
Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor 

to the trailing edge of the blade.

WARNING:

 To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked “Acceptable for Fan Support of 15.9 kg (35 lbs) or 

less” and use mounting screws provided with the outlet box.

CAUTION

: Comply with local codes and regulations. If installing the secondary support safety cable in the U.S., do not remove knockouts in the outlet 

box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to the building structure or the ceiling joist.

WARNING:

 To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert 

foreign object between rotating blades.
Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING:

 To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. JY1126O manufactured by Satellite 

Electronic (Zhongshan) Ltd. 

WARNING:

 To reduce the risk of fire or electric shock, do not use this fan with any other solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment 

manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for 

Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION:

 To reduce the risk of electric shock, disconnect the electrical supply circuit to the fan before installing the light kit.

CAUTION:

 The light source is designed for this specific application and can overheat if serviced by untrained personnel. If any servicing is required, the 

product should be returned to an authorized service facility for examination or repair.  
All set screws must be checked and tightened where necessary before installation.

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, FOLLOW THESE INSTRUCTIONS.

Summary of Contents for 5LWDSM60 D Series

Page 1: ...AME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 5LWDSM60XXXD Series Fan cETL Model NO 5LWDSM60XXD 7 62 kg 16 8 lbs Owner s Guide and Installation Manual ...

Page 2: ...pport safety cable in the U S do not remove knockouts in the outlet box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades At...

Page 3: ...e outlet box Partially loosen the two screws on the outlet box attach the mounting bracket onto the outlet box by sliding it over the two screws as shown in the illustration Have the mounting bracket in position and tighten the set screws Partially loosen downrod set screws from yoke at top of motor assembly Remove preassembled keeper pin and cross pin from downrod Keep parts Place downrod over ca...

Page 4: ...The Secondary Support Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box Make wiring connections using wire connectors provided as indicated above Brown wire from fan to Brown wire from receiver marked Motor U Gray wire from fan to Gray wire from receiver marked Motor V Orange wire from fan to Orange wire from receiver marked Motor W White wire from fan marked For light to White wir...

Page 5: ...s securely Repeat this process for remaining blade assemblies Connect the light lead wires from fan to LED light fixture with a quick connector as shown in the illustration Note Be sure quick connector clasped together completely Install the LED light fixture onto the hub on the fan Place light lead wires in the hub and attach LED light fixture onto the hub by locating ridges in the LED light fixt...

Page 6: ...fan will operates randomly among minimum low and medium low speed at intervals of 30 seconds until the breeze mold is canceled Breeze mode can be erased by pressing either the power or speed control buttons Note This remote controller has auto resume function The fan and light will maintain the last setting when turned back on with the exception of Breeze mode Battery cover DIM D ON OFF O SET SET ...

Page 7: ...matically after installation it is still using the factory setting Follow the settings for Learn Mode above to reset 2 If the fan or light isn t working reset power turn the power off then turn the power back on and follow the Universal Mode or Learn Mode remote control settings 3 If two or more fans in the same remote signal range are on the same power supply they cannot be operated separately by...

Page 8: ...from multiple smart phones or tablets by logging onto the same Bond Home account on all the smart phones tablets Fan operation with Bond Home APP Compatible with Amazon Alexa Google Home and Samsung SmartThings Tap Settings on the bond app select Manage Integrations and you may find the Smart Cloud integrations Or you may download Alexa Google Home Samsung SmartThings app You may need to sign up a...

Page 9: ...ounting bracket or mounting plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceiling Keeping measure within 1 8 rotate the fan until the next blade is positio...

Page 10: ...Jun 2021 Nov 2021 update about Bond App Dec 2021 update step 11 with step screw ...

Reviews: