background image

Installation work and electrical wiring must be done by qualified person(s) in accordance with  applicable codes and standards (ANSI/NFPA 70-

1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacurer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on

one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being

switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such  as a tag,

to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from

the floor to the trailing edge of the blade.

To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support. Use only the

screws provided with the outlet box. (Mounting must support at least 35 lbs. (16kg.)).

Do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equip-

ment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American

Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched

on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such  as a tag, to the

service panel.

Note - For Outdoor Fans Only: Suitable for use in damp locations when installed in a GFCI protected branch circuit.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

Installation

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

S

AFETY

T

IPS

TTO

OO

OLLSS R

REEQ

QU

UIIR

REED

D

PPhhiilllliippss SSccrreew

wddrriivveerr      W

Wiirree CCuutttteerrss       PPlliieerrss

SStteepp LLaaddddeerr

Before you begin installing the fan, Switch

power off at Service panel and lock service dis-

connecting means to prevent power from being

switched on accidentally.  When the service dis-

connecting means cannot be locked, securely

fasten a prominent warning device, such  as a

tag, to the service panel.

1

Loosen lock nuts and screws on yoke

till you can not feel screw on inside

of yoke.

Remove keeper from cross pin and

then cross pin from yoke. Replace

keeper on cross pin and save.

4

Remove 6 yoke screws and save.

6

Before installing this fan make sure the outlet

box is properly installed to the house structure.

To reduce the risk of fire, electric shock, or per-

sonal injury, mount to outlet box or supporting

system acceptable for fan support. (Mounting

must support at least 35 lbs.(16 kg.)).

2

Use metal outlet box suitable for fan support

(must support 35 lbs). Before attaching fan to

outlet box, ensure the outlet box is securely

fastened by at least two points to a structural

ceiling member ( a loose box will cause the fan

to wobble).

Use only the screws pro-

vided with the outlet box.  

3

5

Summary of Contents for 5LNR52XXD Series

Page 1: ...Quality Ceiling fans Owner s Manual Ceiling Fan Installation Instructions For 5LNR52XXD Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weigh with light ...

Page 2: ...ed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power...

Page 3: ...r Make wiring connections as indicated above White from fan to white from remote marked N Blue from fan to blue from remote marked light Black from fan to Black from remote marked L White from house to white from remote marked AC N Black from house to Black from remote marked AC L Connect all green ground wires to Ground wire from House white black 18 Remove upper motor housing 7 Place blades in t...

Page 4: ...sen 2 screws and remove 1 screw Save screw removed 21 Place light kit over screws and twist into place Then tighten all 3 screws securely 22 Plug white wire from fan to white wire from light kit Then plug black wire from fan to black wire from light kit 23 Place heat shield over screws and twist into place Then tighten all 3 screws securely 24 Install the 3 x 40 watt incandescent candelabra bulbs ...

Page 5: ... 34 Remove cover by snaping off from top or bot tom Remove battery cover Install 12V battery into wall remote Duracell MN21 Eveready A23 GP 23A all 12V Place face plate over battery compartment and buttons Place remote over 2 pins on front cover Attach cover of remote by placing over 4 pins and snaping into place 32 31 HAND HELD INSTALL WALL MOUNT INSTALL ...

Page 6: ...immer once quickly To turn off press once quickly while light is on To dim light hold down button light dimmer The light will cycle from bright to dim to bright until button is released Light will maintain last setting if turned off HIGH SPEED MEDIUM SPEED LOW SPEED FAN OFF SETTING Turns fan off only LIGHT ON OFF SET TING AND DIMMER Press and hold to dim light infinitively LED LIGHT ...

Page 7: ...t blade is posi tioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the mo...

Page 8: ...6 21 06 REV 0 New made from 5GMR manual ...

Reviews: