After making the wire connections, the wires 

should be spread apart with the grounded 

conductor and the equipment-grounding 

conductor on one side of the outlet box and 

ungrounded conductor on the other side of 

the outlet box. The splices after being made 

should be turned upward and pushed carefully 

up into the outlet box.              

Insert blade into the slot on flywheel.

Install blade with screws and fiber 

washers provided, aligning each of the 

holes as shown and tighten all screws 

securely. Repeat this process for 

remaining blades. 

Install 2 of the screws to the side panel of 

mounting bracket corresponding to the 

open slotted holes on the canopy upper 

rim, screws provided. Remove the thread 

studs from the lower part of the mounting 

bracket.
Lift fan to mounting bracket, aligning the 

“L” shape holes on canopy with the 

screws on the mounting bracket. Turn the 

fan clockwise to lock in position. Install 

the other 2 canopy mounting set screws 

from the hardware pack and tighten all 

screws securely.

Loosen 2 and remove 1 preassembled 

screw from the plate on motor. Save 

screw for later use.

Connect the quick connector from fan to 

the quick connector from switch house 

(light pan). Be sure they are clasped 

together firmly. 

Place light pan over the lead wires and 

attach it onto the plate on motor, aligning 

the keyhole slots on the light pan with the 

preassembled screws on the plate. Twist 

clockwise till lock.

Reinstall the screw removed in step 21. 

Tighten all screws securely.

Loosen 2 and remove 1 preassembled 

screw from light pan. Save screw for later 

use.

Blade

Light pan

Light pan

Plate on motor

Grounded

wires

Ungrounded

wires

Summary of Contents for 5DIC44XXXD-V1 Series

Page 1: ...E OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 5DIC44XXXD V1 Series Fan CUL Model NO 5DIC44XXXD V1 7 9 kgs 17 4 lbs ...

Page 2: ...edge of the blade WARNING To Reduce The Risk Of Fire Electric Shock or Personal Injury Mount To Outlet Box Marked Acceptable for Fan Support of 15 9 kg 35 lbs or less And Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box Mount the secondary su...

Page 3: ... structural ceiling member a loose box will cause the fan to wobble Remove the two outlet box screws provided with the box aligning the holes of the mounting bracket with the holes of the outlet box Reinstall the 2 outlet box screws securely Partially loosen downrod set screws from yoke at top of motor assembly Remove preassembled cross pin and keeper pin from downrod Save parts Place downrod over...

Page 4: ...nnectors provided as indicated above White from fan to White Neutral from house Black and Blue from fan to Black Live from house Connect all green grounded wires to Grounded wire from House Make sure that no filaments are outside of the wire connectors After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of...

Page 5: ...emove Knockouts In The Outlet Box Make wiring connections using wire connectors provided as indicated above White from fan to White Neutral from house Black and Blue from fan to Black Live from house Connect all green grounded wires to Grounded wire from House Make sure that no filaments are outside of the wire connectors After making the wire connections the wires should be spread apart with the ...

Page 6: ...thread studs from the lower part of the mounting bracket Lift fan to mounting bracket aligning the L shape holes on canopy with the screws on the mounting bracket Turn the fan clockwise to lock in position Install the other 2 canopy mounting set screws from the hardware pack and tighten all screws securely Loosen 2 and remove 1 preassembled screw from the plate on motor Save screw for later use Co...

Page 7: ...all the screw removed in step 23 Tighten all screws securely Setting the reverse switch in the left hand side will result in downward airflow and setting the switch in the right hand side will result in upward airflow Note Reverse switch must be set either way completely If the reverse switch is set in the middle position fan will not operate Attach glass by locating dimples in light pan with groo...

Page 8: ...plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measurement Repeat fo...