background image

3

© 2014 Monte Carlo Fan Company

11/1/2014

1

2

3

4

5

6

ON

OFF

ON

OFF

Before you begin installing the fan, Switch 

power off at Service panel and lock 

service disconnecting means to prevent 

power from being switched on 

accidentally. When the service 

disconnecting means cannot be locked, 

securely fasten a warning device, such  

as a tag, to the service panel.

Use AC 120V/60HZ power supply 

only.

Before installing this fan make sure the 

outlet box is properly installed to the 

house structure. To reduce the risk of 

fire, electric shock, or personal injury, 

mount to outlet box or supporting system 

acceptable for fan support. 

(Mounting must support at least 35 lbs.)

Use metal outlet box suitable for fan 

support and use only the screws provided 

with the outlet box  (must support 35 lbs). 

Before attaching fan to outlet box, ensure 

the outlet box is securely fastened by at 

least two points to a structural ceiling 

member ( a loose box will cause the fan to 

wobble). Remove the two outlet box 

screws provided with the box, aligning 

the holes of the mounting bracket with 

the holes of the outlet box. Reinstall the 2 

outlet box screws securely.

Partially loosen downrod set screws from 

yoke at top of motor assembly.

Remove preassembled cross pin and 

keeper pin from downrod. 

Place downrod over canopy and yoke 

cover. Thread lead wires and safety cable 

from motor assembly through downrod.

Slip downrod into motor housing yoke, 

aligning holes and install cross pin and 

keeper pin. 

Insert cross pin through yoke and downrod 

until point appears on the other side, and 

insert keeper pin on cross pin. 

Pull the downrod up tight against the 

cross pin, and then evenly tighten the 

downrod set screws on motor housing 

yoke. 

Place yoke cover on top housing of fan.

Warning

: Cross pin and keeper pin must be 

installed securely, failure to install them will 

result in serious injury.

Yoke cover

Mounting bracket

Downrod

Cross pin

Cross pin

Keeper pin

Keeper pin

Canopy

Downrod

Summary of Contents for 5AZR56 Series

Page 1: ...t DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 5AZR56XX Series Fan UL Model NO 5AZR56XX 11 5 kgs 25 3 lbs ...

Page 2: ...rsonal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To reduce the risk of fire or electric shock this fan must be installed with an isolating wall control switch WARNING To reduce the risk of fire or electric sho...

Page 3: ... points to a structural ceiling member a loose box will cause the fan to wobble Remove the two outlet box screws provided with the box aligning the holes of the mounting bracket with the holes of the outlet box Reinstall the 2 outlet box screws securely Partially loosen downrod set screws from yoke at top of motor assembly Remove preassembled cross pin and keeper pin from downrod Place downrod ove...

Page 4: ...rent positions to have separate control Make wire connections using wire connectors provided as indicated above White from fan to White from remote marked N Blue from fan to Blue from remote marked For Bottom Light Orange from fan to orange from remote marked For Upper Light Black from fan to Black from remote marked L White from house to White from remote marked AC N Black from house to Black fro...

Page 5: ...ighten all screws securely Attach switch housing onto top plate aligning the holes and reinstall the 3 set screws removed in step 15 and tighten all screws securely Remove battery cover Install 12V battery into wall remote Duracell MN21 Evereday A23 GP 23A all 12V Attach cover of remote by placing over buttons and snap the battery cover in place Place battery cover over battery compartment and but...

Page 6: ...e Carlo Fan Company 11 1 2014 19 20 Install wall control unit to outlet box using machine screws provided Attach front cover to wall control unit with screws provided Snap battery cover in place WALL MOUNT INSTALL ...

Page 7: ... light dimmer once quickly To turn off press once quickly while light is on To dim light hold down button light dimmer The light will cycle from bright to dim to bright until button is released Light will maintain last setting if turned off UP LIGHT ON OFF To turn light on press light button To turn off press light button while light is on FORWARD REVERSE Depress reverse button with fan running Al...

Page 8: ...N LQ SHULRG RI KRXUV 0RVW QRLVHV DVVRFLDWHG ZLWK D QHZ IDQ ZLOO GLVDSSHDU DIWHU WKLV SHULRG I WKLV LV D GRZQURG PRXQW IDQ PDNH VXUH WKH ULGJH RQ PRXQWLQJ EUDFNHW HQJDJHV WKH QRWFK LQ WKH GRZQURG EDOO 0DNH VXUH WKDW FDQRS PRXQWLQJ EUDFNHW RU PRXQWLQJ SODWH DUH WLJKWHQHG VHFXUHO WR FHLOLQJ MXQFWLRQ ER DQG MXQFWLRQ ER LV PRXQWHG UPO WR FHLOLQJ MRLVW KHFN WKDW DOO EODGHV DUH VFUHZHG UPO LQWR EODGH KRO...

Page 9: ...Nov 2014 Aug 2015 change uplight with on off ...