Installation work and electrical wiring must be done by qualified person(s) in accordance with  applicable codes and standards (ANSI/NFPA 70-

1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacurer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on

one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being

switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such  as a tag,

to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from

the floor to the trailing edge of the blade.

To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support. 

(Mounting must support at least 35 lbs. (16kg.)).

Do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equip-

ment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American

Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched

on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such  as a tag, to the

service panel.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

Installation

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

S

AFETY

T

IPS

TTO

OO

OLLSS R

REEQ

QU

UIIR

REED

D

PPhhiilllliippss SSccrreew

wddrriivveerr      W

Wiirree CCuutttteerrss       PPlliieerrss

SStteepp LLaaddddeerr

Before you begin installing the fan, Switch

power off at Service panel and lock service dis-

connecting means to prevent power from being

switched on accidentally.  When the service dis-

connecting means cannot be locked, securely

fasten a prominent warning device, such  as a

tag, to the service panel.

1

Install 4 x 25 watt candelabra base

bulbs included.

4

Before installing this fan make sure the outlet

box is properly installed to the house structure.

To reduce the risk of fire, electric shock, or per-

sonal injury, mount to outlet box or supporting

system acceptable for fan support. (Mounting

must support at least 35 lbs.(16 kg.)).

2

Install  the Mountiing Bracket to the

Outlet box.  Use only the screws

provided with the outlet box.  

3

Loosen set screws on yoke.

6

Remove cotter and keeper pin from

yoke.

5

Summary of Contents for 5AYR54 Series

Page 1: ...Quality Ceiling fans Owner s Manual Ceiling Fan Installation Instructions For 5AYR54 Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weigh with light ...

Page 2: ...alled over a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Associatio...

Page 3: ...the Receiver are set to the same position See Fig 37 for remote operation orange blue Green white black House Fan 13 14 Check the motor for plastic shipping sta bilizer tabs and remove if they are pres ent The screws washers and motor pads are pre installed to the blade holders Attach blade assembly to motor and tight en screws securely 17 Hang fan from mounting bracket 10 Install keeper into cros...

Page 4: ...ss and place over the 2 screws and twist to hold in place Replace screw removed 19 Install 3x 40 watt candelabra base bulbs included 27 Place the finial cap on and twist to tighten 29 Place light kit over screws and twist to lock into place Tighten 3 screws securely 26 FOR LIGHT KIT INSTALL SKIP THIS STEP Attach center cover plate by screwing into center of fan 23 Remove cover by snaping off from ...

Page 5: ...n front cover Attach cover of remote by placing over 4 pins and snaping into place 31 HAND HELD INSTALL Install wall control unit to outlet box using machine screws provided 32 Attach front cover to wall control with screws provided Snap battery cover in place 33 WALL MOUNT INSTALL ...

Page 6: ...right to dim to bright until button is released Light will maintain last setting if turned off FORWARD REVERSE Depress rev button allow a few seconds for remote to change rotation direction with fan running HIGH SPEED MEDIUM SPEED LOW SPEED FAN OFF SETTING Turns fan off only FAN REVERSE Press once to change direction of the fan Fanmust be running to reverse UPLIGHT ON OFF SET TING AND DIMMER Press...

Page 7: ...peat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if...

Page 8: ...9 21 04 REV 0 New made from 5AHR manual ...

Reviews: