3

© 2015 Monte Carlo Fan Company

12/2017

1

2

3

4

5

6

ON

OFF

ON

OFF

Before you begin installing the fan, Switch 

power off at Service panel and lock 

service disconnecting means to prevent 

power from being switched on 

accidentally. When the service 

disconnecting means cannot be locked, 

securely fasten a warning device, such  

as a tag, to the service panel.

Before installing this fan make sure the 

outlet box is properly installed to the 

house structure. To reduce the risk of 

fire, electric shock, or personal injury, 

mount to outlet box or supporting system 

acceptable for fan support. 

(Mounting must support at least 35 lbs.)

Use metal outlet box suitable for fan 

support and use only the screws provided 

with the outlet box  (must support 35 

lbs). Before attaching fan to outlet box, 

ensure the outlet box is securely fastened 

by at least two points to a structural 

ceiling member ( a loose box will cause 

the fan to wobble). Remove the two outlet 

box screws provided with the box, 

aligning the holes of the mounting 

bracket with the holes of the outlet box. 

Reinstall the 2 outlet box screws 

securely.

Remove shipping stabilizers from motor.

Partially loosen downrod set screws from 

yoke at top of motor assembly.

Remove preassembled cross pin and 

keeper pin from downrod. 

Place downrod over canopy and yoke 

cover. Thread lead wires and safety cable 

from motor assembly through downrod.

Slip downrod into motor housing yoke, 

aligning holes and install cross pin and 

keeper pin. 

Insert cross pin through yoke and downrod 

until point appears on the other side, and 

insert keeper pin on cross pin. 

Pull the downrod up tight against the 

cross pin, and then evenly tighten the 

downrod set screws on motor housing 

yoke. 

Place yoke cover on top housing of fan.

Warning

: Cross pin and keeper pin must 

be installed securely, failure to install them 

will result in serious injury.

Yoke cover

Mounting bracket

Downrod

Cross pin

Cross pin

Keeper pin

Keeper pin

Shipping stabilizer

Downrod

Canopy

Summary of Contents for 3VNMR56 D-V1 Series

Page 1: ...OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com...

Page 2: ...ructure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rota...

Page 3: ...x will cause the fan to wobble Remove the two outlet box screws provided with the box aligning the holes of the mounting bracket with the holes of the outlet box Reinstall the 2 outlet box screws secu...

Page 4: ...be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splices after being mad...

Page 5: ...d setting the switch on the right hand side will result in upward airflow Note Reverse switch must be set either way completely If the reverse switch is set in the middle position fan will not operate...

Page 6: ...nte Carlo Fan Company 12 2017 19 Attach blanking plate assembly onto light pan by locating dimples in light pan with grooves in blanking plate and twist clockwise until tight Blanking plate assembly L...

Page 7: ...wires from fan Connect the black white wire marked AC IN L from wall controller to the HOT wire from house and then connect the black wire marked TO MOTOR L of wall controller to the fan lead wire fr...

Page 8: ...LQ SHULRG RI KRXUV 0RVW QRLVHV DVVRFLDWHG ZLWK D QHZ IDQ ZLOO GLVDSSHDU DIWHU WKLV SHULRG I WKLV LV D GRZQURG PRXQW IDQ PDNH VXUH WKH ULGJH RQ PRXQWLQJ EUDFNHW HQJDJHV WKH QRWFK LQ WKH GRZQURG EDOO 0D...

Page 9: ...Mar 2018 V1 edition...