5

© 2018 Monte Carlo Fan Company

09/2018

13

14

15

Make wiring connections using wire connectors provided as indicated above.  

Red from fan to Red from receiver marked Motor U.

Purple from fan to Purple from receiver marked Motor V.

Brown from fan to Brown from receiver marked Motor W.

White from fan marked “For light” to White from receiver marked “For light”.

Blue from fan marked “For light” to Blue from receiver marked “For light”.  

White (Neutral) from house to White from remote marked AC IN N. 

Black (Live) from house to Black from remote marked AC IN L. 

Connect all green grounded wires to Grounded wire from House. 

Make sure that no filaments are outside of the wire connectors.

Insert the remote receiver into mounting bracket.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one 

side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices after being made should be turned upward and 

pushed carefully up into the outlet box.              

 

 

Partially loosen 2 of the set screws on 

mounting bracket corresponding to the slotted 

holes on the canopy upper ring. Remove the 

other 2 set screws. Save screws. 

Raise canopy to mounting bracket, aligning 

loosened screws in mounting bracket with 

slotted holes in canopy. Twist canopy 

clockwise to lock. Reinstall the screws just 

removed and then tighten all screw securely

Install canopy ring onto canopy by aligning the 

grooves in canopy ring with the humps on 

canopy and snap it onto canopy. 

Attach glass to light pan by locating 

dimples in light pan with grooves in glass 

and twist clockwise until tight.

    

Gr

een Fr

om Hanger Ball

Gr

een Fr

om Mounting Bracket

Motor U- Red

Motor V- Purple

Motor W- Br

own

Hump

Groove

Canopy ring

Receiver


Glass

Light pan

Receiver

White- AC IN N

Black- AC IN L

Gr

een or Bar

e Gr

ound

W

all Switch

120V Supply

(Power Supply)

To Motor U- Red

To Motor V- Purple
To Motor W- Brown

Black (Live)

White (Neutral)

Light White

Light Blue

To Light White
To Light Blue

Summary of Contents for 3OVR60

Page 1: ...OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com...

Page 2: ...o Not Remove Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist Attach the mount...

Page 3: ...ox Reinstall the 2 outlet box screws securely For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and downrod modes the safety cable must be installed into t...

Page 4: ...to install them will result in serious injury Install ball end of downrod into mounting bracket opening Align engage slot on ball with tab on mounting bracket Warning Failure to align slot on ball wi...

Page 5: ...or on the other side of the outlet box The splices after being made should be turned upward and pushed carefully up into the outlet box Partially loosen 2 of the set screws on mounting bracket corresp...

Page 6: ...ntroller is ready to use Fig 3 Note If using universal mode your fan can be controlled with other remote transmitters with the same setting To control the fan with specific remote transmitter choose L...

Page 7: ...operate the remote setting for more than one fan in the same room in the area where remote signal can reach to if they share the same power supply Separate power supplies like as using individual wal...

Page 8: ...late are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point...

Page 9: ...Oct 2018...

Reviews: