background image

Tighten the  2 set screws on the

yoke once the downrod is in place.

42

Hold the motor housing and turn mount-

ing plate clockwise by screwdriver to hold

it with housing in position. Make sure

that the clips are engaged with the

mounting plate well. 

44

Place the motor housing on the polyfoam

as shown, then locate the mounting plate

to the housing by aligning the clips on

the housing with holes in the mounting

plate

43

Clip

Clip in 

posi-

tion

Thread the lead wires through the

motor housing cover

45

46

Place motor housing cover over the

mounting plate.

Install motor housing cover to the

mounting plate with 3 screws. 

47

Thread the leadwires through the

canopy and Place the canopy over

the downrod.

48

Thread the leadwires through the

hanger ball and place onto the

downrod.

49

Position the pin through the two

holes in the downrod and align the

hanger ball so the pin is captured in

the groove in the top of the hanger

ball. 

note: pin must be installed

with downrod and hanger ball. 

50

Pull the hanger ball up tight against

the pin and securely tighten the

setscrew in the hanger ball. 

a loose

setscrew could create fan 

wobble.

51

Hang assembled fan to the mounting

bracket installed to ceiling in previous

step.

52

Fan and light kit combinations over 35 lbs, in

both flush and downrod mode the safety cable

must be installed into the house structure

beams using the 3” lag screws,washers, and

lock washers. provided.  Make sure that when

the safety cable is fully extended the leadwires

are longer than the cable and no stress is

placed on the leadwires.

53

Safety cable installation

Safety cable

Lag Screw

safety

cable

3” lag

screw

lock

washer

washer

Summary of Contents for 3BvR52XXd-L Series

Page 1: ...ing Fan Installation Instructions For 3BvR52XXd L Series Fan Read and Save TheSe InSTRucTIonS Total fan weight with lights Flush Mount No light kit Downrod with light kit Flush Mount Light kit Downrod...

Page 2: ...s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrig...

Page 3: ...ots in the motor bracket Securely tighten the locknuts onto the threaded studs 11 Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut...

Page 4: ...plug from fan to plug from switch cap 21 Remove the double sided sticky tape and stick the capacitor to the switch cap plate Receiver needs to be stuck to the switch cap plate also by using 2 double s...

Page 5: ...structural ceiling member a loose box will cause the fan to wabble use only the screws provided with the outlet box 32 Thread leadwires and safety cable through the mounting plate Loosen the 2 set scr...

Page 6: ...through the hanger ball and place onto the downrod 49 Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger bal...

Page 7: ...n to the White or Neutral wire from the power source Connect the black wire from the fan to the Black or hot wire from the power source Connect all Green Yellow wires from the fan Downrod and mounting...

Page 8: ...mmer once quickly To turn off press once quickly while light is on To dim light hold down button light dimmer The light will cycle from bright to dim to bright until button is released Light will main...

Page 9: ...ween the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Rever...

Page 10: ...pour l installation d un ventilateur de plafond Poids total du ventilateur LIRE ET GARDER CES INSTRUCTIONS Por 3BVR52XXD L Ventilateurs Tige avec le kit l ger Tige sans kit l ger B ti affleurant kit l...

Page 11: ...tilateur Le montage doit supporter au moins 35 lbs 16 kg 9 Ne pas plier les porte pales au cours de l installation sur le moteur de l quilibrage ou du nettoyage Ne pas ins rer de corps tranger entre l...

Page 12: ...e de moteur Serrez solidement les contre crous sur les goujons filet s 11 Serrez la vis en bois fixant le c ble de s ret 7 10 tablissez les rapports de fil la source d n ergie utilisant des crous de f...

Page 13: ...peau de finial de l assembleur 23 Pour le ventila teur avec le kit l ger vont tape 21 25 Pour le ventila teur en dehors l e kit l ger vont tape26 31 Enlevez le double a d grossi bande collante et coll...

Page 14: ...parfaitement attach e au moins en deux points une pi ce de charpente du pla fond une bo te de sortie de courant mal attach e provoquera des secousses du ventilateur Utilisez uniquement les vis fourni...

Page 15: ...Remarque l Epingle doit tre install e avec la tige et la fixation 50 Remonter la fixation fermement con tre l pingle et bien serrer les vis dans la fixation Une vis desserr e pourrait amener le venti...

Page 16: ...la bo te de sortie et le conducteur sans mise la terre de l autre c t de la bo te de sortie Des fils piss s devraient tre tourn s vers le haut et pouss s soigneusement vers le haut dans la bo te de so...

Page 17: ...serrez une fois rapidement tandis que la lumi re est allum e Pour obscurcir la lumi re maintenez le bouton grada teur l ger La lumi re fera un cycle de lumineux pour obscurcir lumineux jusqu ce que l...