Monte Carlo Fan Company 014817595710 Owner'S Manual And Installation Manual Download Page 5

5

© 2015 Monte Carlo Fan Company

5/10/2015

12

13

14

15

16

17

Remove side covers from canopy 

exposing  4 holes.  2 closed holes and 2 

open “L” shape holes. 

Reinstall the 3 set screws remove in step 

11. Tighten screws securely. 

To prepare the fan for wiring, hang fan 

onto mounting bracket by sliding the 

canopy over the mounting bracket hook 

(

Use one of non-slotted holes on the 

rim of the canopy

).

For Canadian installation and for USA fan 

and light kit combinations over 35 lbs, in 

both flush and downrod modes the safety 

cable must be installed into the house 

structure beams using 3” lag screws, 

washers and lock washers provided. 

Make sure that when the safety cable is 

fully extended the lead wires are longer 

than the cable and no stress is placed on 

the lead wires.

Note

: If Installing The Secondary Support 

Safety Cable in the U.S., Do Not Remove 
Knockouts In The Outlet Box.

 

Make wiring connections using wire 

connectors provided as indicated above.  

White from fan to White (Neutral) from 

house .  Black and Blue from fan to Black 

(Live) from house. Connect all green 

grounded wires to Grounded wire from 

House. Make sure that no filaments are 

outside of the wire connectors.

Place canopy and rubber pad over lead 

wire and safety cable and align the larger 

holes in canopy and holes on rubber pad 

with the set screws on yoke. 

 

Side cover

Rubber pad 

Lag screw

Safety cable

Washer

Lock washer

Hook

SAFETY CABLE INSTALLATION

Grounded/

Green

Wall 

switch

Power

source

White

(Natural)

Black

(Live)

Black

Blue

White

Summary of Contents for 014817595710

Page 1: ...OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com...

Page 2: ...clearance of 7 feet from the floor to the trailing edge of the blade WARNING To Reduce The Risk Of Fire Electric Shock or Personal Injury Mount To Outlet Box Marked Acceptable for Fan Support of 15 9...

Page 3: ...ember a loose box will cause the fan to wobble Remove the two outlet box screws provided with the box aligning the holes of the mounting bracket with the holes of the outlet box Reinstall the 2 outlet...

Page 4: ...ort Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box Make wiring connections using wire connectors provided as indicated above White from fan to White Neutral from house Black and Blu...

Page 5: ...e safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires Note If Installing The Secondary Support Safety Cable in the U S Do Not Remove Knock...

Page 6: ...by 3 blade screws and washers provided Tighten screws securely Repeat this process for remaining blades Remove shipping stabilizers from motor assembly Install the blade assembly to motor using the p...

Page 7: ...nial as glass may crack or break Setting the reverse switch in the left hand side will result in downward airflow and setting the switch in the right hand side will result in upward airflow Note Rever...

Page 8: ...VDSSHDU DIWHU WKLV SHULRG I WKLV LV D GRZQURG PRXQW IDQ PDNH VXUH WKH ULGJH RQ PRXQWLQJ EUDFNHW HQJDJHV WKH QRWFK LQ WKH GRZQURG EDOO 0DNH VXUH WKDW FDQRS PRXQWLQJ EUDFNHW RU PRXQWLQJ SODWH DUH WLJKWH...

Page 9: ...Mar 2019 5COM52XXD V1...

Reviews: