background image

RMD2400 - RMD2400HD

  |  Owner’s manual

 

RMD2400 - RMD2400HD

IMPORTANT SAFETY INSTRUCTIONS 

• Read these instructions.
• Follow all instructions.
• Keep these instructions.
• Heed all warnings.
• Only use attachments/accessories specified by the man-

ufacturer.

• Power Cord and Plug

Do not defeat the safety purpose of the polarized or grounding 
type plug.
A polarized plug has two blades with one wider than the other.  
A grounding type plug has two blades and a third grounding  
prong. The wide blade or the third prong are provided for  your  
safety. 
If the provided plug does not fit into your outlet, consult an  
electrician for replacement of the obsolete outlet.

Protect the power cord from being walked on or pinched par-
ticularly at plugs, convenience receptacles, and the point 
where they exit from the apparatus.

• Cleaning

When the apparatus needs a cleaning, you can blow off dust 
from the apparatus with a blower or clean with rag etc.

Don’t use solvents such as benzol, alcohol, or other fluids with 
very strong volatility and flammability for cleaning the appara-
tus body. Clean only with dry cloth.

• Servicing

Refer all servicing to qualified personnel. To reduce the risk 
of  electric shock, do not perform any servicing other than that 
contained in the operating instructions unless you are quali-
fied to do so.

Servicing is required when the apparatus has been damaged 
in any way, such as power supply cord or plug is damaged, liq-
uid has been spilled or objects have fallen into the apparatus,  
the apparatus has been exposed to rain or moisture, does not 
operate normally, or has been dropped.

The mains plug is used as the disconnect device, the discon-
nect device shall remain readily operable.

Changes or modifications to this unit not expressly approved 
by the party responsible for compliance could void the user’s 
authority to operate the equipment.

FCC Rules and Regulations

MARKUS wireless receivers are certified under FCC Rules part 
15 and transmitters are certified under FCC Rules part 74. Li-
censing of MARKUS equipment is the user’s responsibility and 
licensability depends on the user’s classification, application 
and frequency selected.

NOTE

This equipment has been tested and found to comply with the 
limits for a class B digital device, pursuant to Part 15 of the 
FCC Rules.These limits are designed to provide reasonable 
protection against harmful interference in a residential instal-
lation. This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance 
with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interfer-
ence will not occur in a particular installation. If this equip-
ment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment 
off and on, the user is encouraged to try to correct the interfer-
ence by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different
  from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician 
  for help.

This device complies with Part 15 of the FCC Rules. Opera-
tion is subject to the following two conditions: (1) this device 
may not cause harmful interference and (2) this device must 
accept any interference received, including interference that 
may cause undesired operation.

Montarbo

®

 declares that this wireless microphone is in com-

pliance with the essential requirements and other relevant 
provisions of Directive 1999/5/EC.

Summary of Contents for FiveO RMD2400

Page 1: ...EN OWNER S MANUAL RMD2400 Kit RMD2400HD Kit WIRELESS MICROPHONE ...

Page 2: ...ters though only one RMD2410 or RMD2420 transmitter can be used once The transmit distance is more than 25 meters in open space It is suitable for using in KTV home classroom conference and other audio equipment The system features as follows Operating Band ISM 2 4 GHz free band GFSK digital modulation demodulation Intelligent Frequency Hopping Automatic mute in bad channel quality or high error c...

Page 3: ... Handheld Transmitter 8 Bodypack Transmitter 9 Pairing Instruction 10 Technical Specifications 10 PACKAGE CONTENTS RMD2400 Cod 5O05040 Receiver RMD2440 Handheld Trasmitter RMD2410 Owner s manual Warranty certificate PACKAGE CONTENTS RMD2400HD Cod 5O05041 Receiver RMD2440 Bodypack Trasmitter RMD2420 Headset Microphone RMD2430 Owner s manual Warranty certificate ...

Page 4: ...rt circuit the fuse holder Before replacing the fuse turn OFF the apparatus and dis connected the power source Protective Grounding Make sure to connect the protective grounding to prevent any electric shock before turning ON the apparatus Never cut off the internal or external protective grounding wire or disconnect the wiring of protective grounding termi nal Operating Conditions This apparatus ...

Page 5: ...pressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC Rules and Regulations MARKUS wireless receivers are certified under FCC Rules part 15 and transmitters are certified under FCC Rules part 74 Li censing of MARKUS equipment is the user s responsibility and licensability depends on the user s classification application and frequency ...

Page 6: ...Owner s manual RMD2400 RMD2400HD 6 RMD2400 RMD2400HD DESCRIPTION RECEIVER Front panel Rear panel 1 3 2 DC 12 15V 200 mA UNBALANCED OU T 5 4 ...

Page 7: ...ep the plug from being detached by an accidental tug on the cord The receiver has no power Off On switch The receiver will be energized whenever the power adapter is connected and plugged into the AC outlet Unplug the power supply from the AC outlet when the system is not in use both for safety and conserving energy Antenna Rotate the permanently attached antenna vertically to get the best recepti...

Page 8: ...t of power 1 2 3 HANDHELD TRANSMITTER 2 1 3 RMD2410 transmitter battery selection and installation Two alkaline AA batteries are recommended When inserting the battery observe correct polarity as marked inside the battery compartment Please stop using and change batteries when the led is blinking not in the pairing status which indicates short of power Press the point 3 and slide out the battery c...

Page 9: ...nect the unit with the RDM2430 headset microphone Pin 1 GND Pin 2 Phantom power supply for condenser microphone Pin 3 For guitar bass and keyboards Pin 4 For dynamic or condenser microphone RDM2430 headset microphone Preset Impedance 680 Ω Frequency Response 50 Hz 12 kHz Sensitivity 65 dB 3 dB at 1kHz Directional 12 x 180 mm 0 47 x 7 1 Weight 22g 0 049Ib GAIN Level Control The gain level can be ad...

Page 10: ...D2410 and RMD2420 only one transmitter either RMD2410 or RMD2420 can be used once The last pairing successful transmitter will be the active transmitter until it powered off or exited the pairing So if you paired two transmitters with RMD2440 and want to use the first transmitter you should power off the second transmitter Frequency 2 404 2 476 GHz RF Sensitivity 78 dBm Transmission Distance 25 m ...

Page 11: ...RMD2400 RMD2400HD Owner s manual 11 NOTES ...

Page 12: ...ot be considered responsible for damages which may be caused to people and things when using this product Specifications and features are subject to change without prior notice 2019 Montarbo srl Rev 01 MONTARBO is part of Eko Music Group S p A ekomusicgroup com Registered Office Via Falleroni 92 P O box 58 62019 Recanati MC Italy Offices and Warehouse Via O Pigini 8 Z I Aneto 62010 Montelupone MC ...

Reviews: