background image

12

REV: 06_11_2022

www.montanarigiulio.com

Fig. 2

NOR - Tab 170

INSTALLATION 

HANDSIDE DX

INSTALLATION 

HANDSIDE DX

STANDARD BASE  

Fig. 3

RG200 - Tab 131

Summary of Contents for NOR

Page 1: ...www montanarigiulio com REV 06_11_2022 MANUAL NOR RG200 INSTALLATION USE AND MAINTENANCE SPEED GOVERNORS ...

Page 2: ... for gearboxes gearless speed governors and safety gears You may check your supply configure the inverter download manuals tech reports certificates and much more Search for Montanari Giulio mobile App available on Google Play and App store SCAN THE QR TO DOWNLOAD ANDROID APP SCAN THE QR TO DOWNLOAD iOS APP SCAN THE QR FOR THE DESKTOP APP ...

Page 3: ...1970 Montanari Group has been focused on providing its customers with the best traction machines and components for lifts and escalators We are proud to have you as a customer and user of the Montanari traction machines and we are confident that we can work together for a long time Massimo Montanari CEO of Montanari Group ...

Page 4: ...5 5 1 General description 15 5 2 Components 15 5 3 Mechanical intervention 18 5 4 Electrical intervention 18 6 INSTALLATION AND FIXING 18 6 1 Installation surface Fixing 18 6 2 Installation of ropes 20 6 3 Electrical installation Excess speed contact 21 7 INSTALLATION OF SPEED GOVERNORS WITH OPTIONAL ACCESSORIES 21 7 1 Electrical installation of the REMOTE CONTROL 21 7 2 Protection cover 22 8 OPER...

Page 5: ...5 www montanarigiulio com ENGLISH SPEED GOVERNORS NOR RG REV 06_11_2022 ...

Page 6: ...seful information before and during the installation step It refers to specific parts of the manual It refers to the proper product disposal REV DATE DESCRIPTION EDITED BY VERIFIED BY APPROVED BY 1 30 01 2019 FIRST REDACTION Marketing Dept Ufficio Tecnico Stefano Bertoni STEFANO BERTONI DTE 2 22 07 2019 SECOND REDACTION Marketing Dept Ufficio Tecnico Stefano Bertoni STEFANO BERTONI DTE 3 23 03 202...

Page 7: ...s and the state of the art technical development applied at the time of printing Speed governors are lead sealed A special anti tamper paint was applied on the screws because they cannot be removed The breakage of lead seal and any tampering involves the cancellation of the manufacturer s warranty To make technical improvements Montanari reserves the right if deemed nec essary to modify the units ...

Page 8: ... in order to Avoid damage to property or persons Ensure safe and reliable operation of the unit Avoid breakage and environmental damage due to misuse Immediate voidance of the guarantee in case of Use of components other than those installed Any modification to the governor Destruction of the lead seal removal of commissioning adhesive labels or of the anti tampering paint Wrong maintenance or wro...

Page 9: ...rmation on the warning or identification plates must be complied with These plates must be kept clean and legible at all times Missing plates must be replaced All spare parts can be obtained from Montanari Giulio C PERSONAL PROTECTIVE EQUIPMENT TO BE USED Protection gloves against mechanical injuries Safety shoes 2 3 Proper disposal Respect the environment and dispose of the product according to t...

Page 10: ...EN 81 20 Safety rules for the construction and installation of lifts for the transport of per sons and goods 3 EN 81 50 Safety rules for the construction and installation of lifts Examinations and tests 4 EN 81 21 Safety rules for the construction and installation of lifts for the transport of persons and goods in existing building 3 2 Legal references 2 4 Safety of operators For the safety of ope...

Page 11: ...0 131 139 Fig 3 4 0 15 0 30 6 6 5 One Way Bidirectional No 3 3 Technical data The following drawings show the overall dimensions of NOR RG200 For versions with optional see the specific sections Tab 2 Tab 3 Force produced by the tensio ning mass acting on the axis of the pull pulley N Pull force acting on the safety gear lever DOWNWARDS N UPWARDS N INTERVENTION 288 349 88 ONE WAY 825 862 27 361 30...

Page 12: ...12 REV 06_11_2022 www montanarigiulio com Fig 2 NOR Tab 170 INSTALLATION HANDSIDE DX INSTALLATION HANDSIDE DX STANDARD BASE Fig 3 RG200 Tab 131 ...

Page 13: ...13 www montanarigiulio com ENGLISH SPEED GOVERNORS NOR RG REV 06_11_2022 INSTALLATION HANDSIDE DX NARROW BASE RG200 Tab 139 Fig 4 ...

Page 14: ...nd means of transport Unless otherwise specified the packaging complies with the HPE guidelines It is recommended to verify also the condition of the goods upon receipt In case of damages do not proceed with installation except for Montanari Giulio C authorization Comply with the symbols on the packaging to prevent damage to property or personal injury Here are the meanings of the symbols that may...

Page 15: ...g the excess speed and to intervene both mechanically and electrically as below described the mechanical part activates the safety gear the electric part stops the lift drive Note A tension device is required to tension the speed governor rope see for example TAB163 1 and TEV on product general catalogue of Montanari Giulio C 5 2 Components The following figures show the parts forming the NOR RG R...

Page 16: ...16 REV 06_11_2022 www montanarigiulio com Label Fig 7 7 Safety Contact Fixing base Test groove Fig 8 ...

Page 17: ... ENGLISH SPEED GOVERNORS NOR RG REV 06_11_2022 Pulley Fig 9 2 Lever Label Fig 10 1 Wheel 3 Spring 4 Locking Tooth 1 Spacer pin Fixing base RG200 Tab 170 Arrow showing the engagement direction of the safety gear 2 Remote control ...

Page 18: ...below or above contact the Montanari technical office unless expressly agreed authorised Assembly and installation must be carried out with great care by qualified and trained personnel The manufacturer cannot be held responsible for damage caused by incorrect assembly or incorrect installation Before starting work make sure that adequate lifting and handling equipment is available All fixing poin...

Page 19: ... 11 FIXING The speed governor must be fixed checking its vertical direction with a bubble level or a lead wire MAX ALLOWED SLOPING The speed governor must be installed so that the rope runs parallel in the pulley groove The rope max recommended sloping A is 0 50 Fig 10 Fig 12 A ...

Page 20: ...through the governor towards the safety gear levers 2 Connect the first rope attachment to the same rope and secure it to the safety gear lever 3 Install the tension device following its installation instructions 4 Connect the second head of the rope passing through the tension device to the rope attachment and then to the safety gear lever Fig 13 SPEED GOVERNOR Rope Rope Attachment Tension device...

Page 21: ...s in its seat and that the spring makes it return to 0 position D Test the operation of the contact at the end reset it in case of manual reset 7 INSTALLATION OF SPEED GOVERNORS WITH OPTIONAL ACCESSORIES 7 1 Electrical installation of the REMOTE CONTROL IMPORTANT The remote control is necessary in case of governor installation in inaccessible areas as specified by the standard The remote control a...

Page 22: ...22 REV 06_11_2022 www montanarigiulio com Fig 15 7 2 Protection cover ITEM COMPATIBLE WITH PE00000176 RG200 Standard base PE00000178 RG200 Narrow base PE00000179 NOR RG200 REMOTE CONTROL ...

Page 23: ... test Speed governor with manual intervention Push the lever UPWARDS NOR or DOWNWARDS RG Fig 16 and press and hold to manually activate the speed governor Allow the lift car to slowly descend until the safety gear is engaged Speed governor with remote control Trigger the electromagnet from the control panel to manually activate the speed governor Allow the lift car to slowly descend until the safe...

Page 24: ...lift shaft Electrical intervention Lay the rope on the test groove 1 only for NOR and RH Fig 17 Allow the lift car to descend at the rated speed until the electrical contact has engaged Restore the electrical contact 2 Fig 17 Allow the lift cab to raise at the rated speed until the electrical contact has engaged Do not reset the electrical contact 2 Fig 17 if only mechanical interven tion is to be...

Page 25: ...nt unintentional start up Place a warning sign on the starting switch Fig 18 9 2 Problems causes and solutions The frequency of inspections and tests to ensure safe operation shall be de termined by the competent authority it is recommended that at least two inspections be carried out per year It is recommended to carry out checks and maintenance operation before the functional tests prescribed by...

Page 26: ... modified seals etc This prohibition also applies during repairs It is absolutely forbidden to replace damaged or defective parts unless a written notice has been passed by the staff of Montanari Giulio C Srl IMPORTANT It is absolutely forbidden to leave the system in operation without the speed governor even for short periods After installation or after an initial period of work it may be necessa...

Page 27: ...27 www montanarigiulio com ENGLISH SPEED GOVERNORS NOR RG REV 06_11_2022 ...

Page 28: ...MONTANARI GROUP HEADQUARTER Montanari Giulio C Srl Via Bulgaria 39 41122 Modena Italia Tel 39 059 453611 Fax 39 059 315890 info montanarigiulio com www montanarigiulio com ...