17
MGX75
ENGLISH
REV: 04_07_2022
www.montanarigiulio.com
Fig. 8
6.2 Installation surface
The installation surface must be uniform and level.
The levelling tolerance is 0.2 mm.
The installation surface must be rigid and robust enough to withstand the forces
involved.
6.3 Installation procedure
The gearless machine can be lifted using the eyebolts for the insertion of the
belts or lifting chains (see also the paragraph on storage and handling). Particular
attention is needed to avoid that the gearless machine receives blows in corre-
spondence of the brake disc; the brake levers and the electrical connections of the
board are very delicate. Lifting example Fig. 8.
Place the unit on the installation surface and secure it.
• Fixing screws and nuts must be tightened to the prescribed torque.
• Use bolts with a minimum strength class of 8.8.
• Do not force or hit the fixings to position them; this could damage the
bearings, rings, etc.
• Mount the safety devices.