The Refrigeration and Freezer bases are produced with the best possible material and workmanship. 
PROPER INSTALLATION IS ESSENTIAL FOR SAFE AND EFFICIENT TROUBLE-FREE OPERATION. 

THE INSTALLATION INSTRUCTIONS CONTAINED HEREIN ARE FOR THE  
USE OF QUALIFIED INSTALLATION AND SERVICE PERSONNEL ONLY.  
INSTALLATION OR SERVICE BY OTHER THAN QUALIFIED PERSONNEL 
MAY RESULT IN DAMAGE TO THE EQUIPMENT AND/OR INJURY TO THE         
OPERATOR. 

Qualified installation personnel are individuals, a firm, corporation or company which either in 
person, or through a representative are engaged in, and are responsible for: 

 

A.  The installation or replacement of the connection, installation, repair or servicing of equip-

ment, who is experienced in such work, familiar with all precautions required, and has 
complied with all requirements of state or local authorities having jurisdiction. Reference: 
National Fuel Gas Code Z223.1-latest addenda, Section 1.4. 

 

B.  The installation of electrical wiring from the electric meter, main control box or service out-

let to the electric appliance. Qualified personnel must be experienced in such work, be fa-
miliar with all precautions required and have complied with all requirements of state and 
local authorities having jurisdiction. Reference: National Electric Code, N.F.P.A. No. 70– 
latest addenda. 

 

READ CAREFULY AND FOLLOW THESE INSTRUCTIONS 

THIS UNIT WHEN INSTALLED MUST BE ELECTRICALLY GROUNDED 
IN ACCORDANCE WITH LOCAL CODES, OR IN ABSENCE OF LOCAL 
CODES, WITH THE NATIONAL ELECTRICAL CODE, ANSI/NFPA No.70– 
LATEST ADDENDA. 

PROVISIONS MUST BE MADE FOR ADEQUATE AIR SUPPLY TO THE UNIT. 

Summary of Contents for RB108R

Page 1: ...ed by qualified installation personnel PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE THE MONTAGUE COMPANY 1830 Stearman Avenue P O BOX 4954 Hayward CA 94540 4954 TEL 510 785 8822 FAX 510 785 3342 MOD...

Page 2: ...nd packed by skilled personnel before leaving the factory The transportation company assumes full responsibility for safe delivery upon acceptance of this shipment If shipment arrives damaged 1 VISIBL...

Page 3: ...who is experienced in such work familiar with all precautions required and has complied with all requirements of state or local authorities having jurisdiction Reference National Fuel Gas Code Z223 1...

Page 4: ...rance to walls or other equipment These models are available as self contained or remote Standard features on these models include Electronic temperature control All stainless steel construction 6 leg...

Page 5: ...REEZER SETTING C THERMOSTAT D DEFROST E SHUTTING OFF DRAWER CONFIGURATION PAGE 9 10 MAINTENANCE PROCEDURES PAGE 11 A CLEANING STORAGE CABINET B STORAGE CABINET C CONDENSING UNIT TROUBLESHOOTING GUIDE...

Page 6: ...age Hz Cycle Heaters freezers only Number of Heaters Total Amps Maximum Amp draw Minimum Circuit Minimum Circuit Ampacity Maximum Amps Protection Breaker size Refrigerant Refrigerant type and amount u...

Page 7: ...electrical field SHIPPING DAMAGE CLAIM PROCEDURE NOTE For your protection please note that equipment in this shipment was carefully inspected and packed by skilled personnel before leaving the factor...

Page 8: ...an authorized service technician B ON FREEZER BASE UNITS The temperature control should be set at 0 F with 5 F differential Temperature display should read between 0 F and 5 F C The temperature contro...

Page 9: ...ainless steel track system Recessed drawer handles Drawers are easily removed for cleaning 300lbs 136 kg individual drawer weight capacity Tandem 2 51mm diameter stainless steel wheel Self Contained M...

Page 10: ...Pans Drawer Width Configuration 14 3 8 356mm 22 3 8 566mm 27 1 4 692mm RB 36 R 36 914 C 4 RB 48 R 48 1219 A B 6 RB 60 R 60 1524 B C 8 RB 72 R 72 1829 C 2 8 RB 84 R 84 2134 B 2 C 12 RB 96 R 96 2438 C 3...

Page 11: ...nser Condenser fins that are clogged with dirt and grease greatly reduce required heat transfer to air flow Failure to keep the condenser clean may cause premature compressor failure which will not be...

Page 12: ...askets not sealing properly Condenser dirty Evaporator coil is iced up or dirty Prolonged and or frequent door openings or door s ajar Excessive load of warm food placed into lower storage cabinet 3 L...

Page 13: ...NOID VALVE BLACK BLACK BLACK BLACK HOT WHITE NUETRAL WHITE JUNCTION BOX BLACK WHITE WHITE WHITE GROUND T STAT RED RED 115 V AXIAL FAN 115 V AXIAL FAN ON SELF CONTAINED CABINETS ONLY 115V 60 HZ 1 PH PR...

Page 14: ...EVAPORATOR COIL GROUND WIRE GROUND WIRE FAN MOTOR FAN MOTOR FAN FAN 4 4 N N SOLENOID VALVE BLACK HOT WHITE NUETRAL GROUND JUNCTION BOX BLACK WHITE WHITE WHITE BLACK BLACK RED RED T STAT 1 2 3 WIRING D...

Page 15: ...ON SELF CONTAINED CABINETS ONLY 115V 60 HZ 1 PH 1 3 HP COMPRESSOR PRESSURE SWITCH 10 AMP COMPRESSOR OUTLET 4 4 4 N N 3 3 3 1 2 DEFROST HEATER DEFROST HEATER DEFROST HEATER ONE DOOR 115 V AXIAL FAN 11...

Page 16: ...UND WIRE JUNCTION BOX GROUND BLACK HOT WHITE NUETRAL DEFROST HEATER ONE DOOR SOLENOID VALVE DEFROST HEATER DEFROST HEATER AMBIENT OUTSIDE COIL DEFROST INSTERTED INSIDE EVAPORATOR COIL BLACK BLACK WHIT...

Page 17: ...17 EXPLODED VIEW 1...

Page 18: ...RB 72 SC RB 84 SC RB 96 SC RB 108 SC 10 70085 1RA LOUVER TOP RAIL RB 36 SC RB 48 SC RB 60 SC RB 72 SC RB 84 SC RB 96 SC RB 108 SC 11 70087 8RA LOUVER PANEL RB 36 SC RB 48 SC RB 60 SC RB 72 SC RB 84 S...

Page 19: ...19 17 EXPLODED VIEW 2...

Page 20: ...2 R RB 84 R RB 96 R RB 108 R RB 36 SC RB 48 SC RB 60 SC RB 72 SC RB 84 SC RB 96 SC RB 108 SC 7 70029 0RA TRACK MOUNT FRONT RIGHT RB 36 R RB 48 R RB 60 R RB 72 R RB 84 R RB 96 R RB 108 R RB 36 SC RB 48...

Page 21: ...96 R RB 108 R RB 36 SC RB 48 SC RB 60 SC RB 72 SC RB 84 SC RB 96 SC RB 108 SC 17 60516 6 DIGITAL THERMOSTAT RB 36 R RB 48 R RB 60 R RB 72 R RB 84 R RB 96 R RB 108 R TEMPERATURE PROBE RB 36 SC RB 48 SC...

Page 22: ...22 EXPLODED VIEW 3...

Page 23: ...FACE RB 48 R RB 36 SC RB 60 SC 70160 2RA DRAWER FACE RB 48 R RB 60 R RB 84 R RB 108 R RB 60 SC RB 72 SC RB 96 SC 70106 8RA DRAWER FACE RB 36 R RB 60 R RB 72 R RB 84 R RB 96 R RB 108 R RB 48 SC RB 72 S...

Page 24: ...60 R RB 72 R RB 84 R RB 96 R RB 108 R RB 36 SC RB 48 SC RB 60 SC RB 72 SC RB 84 SC RB 96 SC RB 108 SC 13 59675 2 SPACER RB 36 R RB 48 R RB 60 R RB 72 R RB 84 R RB 96 R RB 108 R RB 36 SC RB 48 SC RB 60...

Page 25: ...36 SC RB 48 SC RB 60 SC RB 72 SC RB 84 SC RB 96 SC RB 108 SC 2 60535 2 LOW PRESSURE SWITCH RB 36 SC RB 48 SC RB 60 SC RB 72 SC RB 84 SC RB 96 SC RB 108 SC 3 60524 7 LIQUID LINE FILTER DRIER RB 36 SC...

Page 26: ...g information Serial No _____________________________________________ Model No _____________________________________________ Change No ____________________________________________ Name No of Part Mode...

Page 27: ...27...

Page 28: ...28 THE MONTAGUE COMPANY 1830 Stearman Avenue P O BOX 4954 Hayward CA 94540 4954 TEL 510 785 8822 FAX 510 785 3342 Rev A P N 61052 6...